{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10N34V100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10N34V100","canonicalUrl":"https://aoctrl.com/schneider/C10N34V100","factsUrl":"https://aoctrl.com/api/mcp/products/C10N34V100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, C10N34V100, earth leakage circuit breaker, 100 A, 3P, MicroLogic 4.2 trip unit, 50 kA Icu at 415 V AC.","salesMarkdown":"The Schneider C10N34V100 is a ComPacT NSX earth leakage circuit breaker, 3-pole, rated 100 A at 40 °C with a MicroLogic 4.2 electronic trip unit. The 90 kA Icu at 240 V AC is the same breaker on a lower-voltage service; the 10 kA at 690 V AC is the ceiling for a 690 V line. What governs the real-world fit is the 100 A trip unit rating and the integrated earth-leakage protection (the R in the protection type set: L for overload, So for short-time short-circuit with fixed delay, I for instantaneous short-circuit, R for earth-leakage). The electronic trip gives you adjustable long-time pickup and delay, plus the earth-leakage function built in — no add-on module needed. Mounts to a backplate — not a DIN rail. The 105 mm width (3-pole frame) and 161 mm height fit standard ComPacT NSX cutouts; the 86 mm depth leaves room for front-connected cables (upside and downside connections are both front-facing). The IP40 front face keeps dust out; the IK07 impact rating handles accidental tool drops during commissioning. The 35 mm connection pitch is the standard busbar or cable-lug spacing for this frame size. ## What the durability numbers mean for a distribution feeder Mechanical durability is 50,000 cycles — that is the handle life, not the electrical contact life. Electrical durability varies by load: 50,000 cycles at 440 V at half rated current (In/2), 30,000 cycles at 440 V at full rated current (In), 20,000 cycles at 690 V at In/2, and 10,000 cycles at 690 V at In. For a distribution feeder that sees infrequent switching (a few operations a year), these numbers are academic — the breaker will outlast the panel. But if this breaker is used as a disconnect that cycles weekly, the 30,000-cycle figure at 440 V In is the one to watch.","metaTitle":"Schneider C10N34V100 ComPacT NSX 100A Earth Leakage Breaker,","metaDescription":"Schneider C10N34V100 ComPacT NSX earth leakage circuit breaker, 100A, 50kA Icu at 415V. MicroLogic 4.2 trip unit with integrated earth-leakage. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Operating mode":"OFF using the IΔn rotary switch","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 4.2","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection R : for earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 40 °C","Breaking capacity":"90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100N","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Overvoltage category":"IV","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"N 50 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"5.8 W N 5.8 W L1 and L3 4.9 W L2","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Class A","Trip unit protection functions":"LSoIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"40...100 A","[Δt] residual earth-leakage time delay adjustment":"0 ms 60 ms 150 ms 500 ms 1 s","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[IΔn] earth-leakage protection sensitivity adjustment range":"30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,045.80 – $1,995.84","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/33281030ada76d33fb027e0096e33841.pdf","sourceUrl":"https://www.se.com/za/en/product/C10N34V100/circuit-breaker-compact-nsx100n-50ka-415vac-3-poles-micrologic-vigi-4-2-trip-unit-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10N34V100/alternatives.json"},"ai":{"faq":[{"question":"What is C10N34V100's breaking capacity at 415 V?","answer":"50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, which is the N-frame breaking capacity code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10N34V100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10N34V100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}