{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10N3MA007","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10N3MA007","canonicalUrl":"https://aoctrl.com/schneider/C10N3MA007","factsUrl":"https://aoctrl.com/api/mcp/products/C10N3MA007","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100N, circuit breaker, 3P, 6.3 A MA magnetic trip, 90 kA Icu at 240 V AC, IEC 60947-2.","salesMarkdown":"It is a 3-pole device (3P) designed specifically for motor protection, providing short-circuit protection (magnetic) only — no thermal overload function. The MA trip unit is the key differentiator here: it responds to magnetic faults only, so it coordinates with an external motor overload relay for thermal protection. This is the standard approach for motor branch circuits where the breaker handles the short-circuit fault clearance and a separate relay handles the running overload. Rated breaking capacity (Icu) per IEC 60947-2 reaches 90 kA at 220/240 V AC, 50 kA at 380/415 V AC, and 10 kA at 660/690 V AC. Under UL 60947-4-1 it carries 85 kA at 240 V AC, 50 kA at 480 V AC, and 10 kA at 600 V AC. The N breaking capacity code (50 kA at 415 V AC) positions this breaker as a standard-duty option for most industrial motor control centers. The 90 kA at 240 V gives headroom for high-fault service entrance applications on the low-voltage side of a step-down transformer. Front connections top and bottom simplify bus-bar and cable routing in a panel. Connection pitch is 35 mm, matching standard bus-bar spacing. IP40 front face protection keeps out tools and fingers; IK07 impact rating handles incidental contact during maintenance.","metaTitle":"Schneider Electric C10N3MA007 ComPacT NSX 100N, 6.3 A MA Tri","metaDescription":"Schneider Electric C10N3MA007 ComPacT NSX circuit breaker. 3-pole, 6.3 A magnetic-only MA trip unit. 90 kA breaking capacity at 240 V AC. IEC 60947-2. Motor protection. Available t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Magnetic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical Life Cycles":"50000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$151.81","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1377928e2d3fd1b3de67ea3e17b47f7e.pdf","sourceUrl":"https://www.se.com/vn/en/product/C10N3MA007/circuit-breaker-compact-nsx100n-50ka-415vac-3-poles-ma-trip-unit-6-3a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10N3MA007/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10N3MA007","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10N3MA007 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}