{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10N44V040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10N44V040","canonicalUrl":"https://aoctrl.com/schneider/C10N44V040","factsUrl":"https://aoctrl.com/api/mcp/products/C10N44V040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, NSX100N frame, 4P, 40 A at 40 °C, 90 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection.","salesMarkdown":"## What this breaker delivers The C10N44V040 is a Schneider Electric ComPacT NSX100N molded-case circuit breaker with a 40 A MicroLogic 4.2 electronic trip unit and integrated earth-leakage protection. It's a 4-pole unit rated for distribution duty, built to EN/IEC 60947-2. At 415 V AC it still holds 50 kA Icu, so it coordinates downstream in a typical 400 V panel. ## Trip unit and protection logic The MicroLogic 4.2 gives you four protection blocks: L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage). The earth-leakage is integrated, no add-on module needed. That saves a slot in the panel and one wiring step during commissioning. Front connections top and bottom — no rear-access requirement, which keeps the panel layout simple. The 35 mm connection pitch matches standard busbar and cable-lug spacing. Neutral is on the left (4P). Mechanical endurance is 50,000 cycles. Electrical endurance at 440 V In is 30,000 cycles — at half load (In/2) it goes to 50,000. At 690 V In it drops to 10,000 cycles. That's typical for a distribution breaker; it's not a switching device for frequent motor starts, but it handles routine isolation and fault clearing without wearing out early.","metaTitle":"Schneider Electric C10N44V040 ComPacT NSX100N, 40 A, 90 kA","metaDescription":"Schneider Electric C10N44V040 ComPacT NSX100N circuit breaker, 40 A at 40 °C, 90 kA Icu at 240 V AC, MicroLogic 4.2 trip unit with integrated earth-leakage protection. Current prod","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical Life Cycles":"50000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,148.69 – $2,155.14","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/551e4de89808f74618b3febcfbbb8165.pdf","sourceUrl":"https://www.se.com/sg/en/product/C10N44V040/circuit-breaker-compact-nsx100n-50ka-at-415vac-micrologic-4-2-vigi-trip-unit-40a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10N44V040/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10N44V040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10N44V040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}