{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10R3MA013","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10R3MA013","canonicalUrl":"https://aoctrl.com/schneider/C10R3MA013","factsUrl":"https://aoctrl.com/api/mcp/products/C10R3MA013","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, C10R3MA013, 3-pole MCCB, 12.5 A, MA magnetic trip unit, 200 kA Icu at 415 V AC, motor protection.","salesMarkdown":"The Schneider Electric C10R3MA013 is a ComPacT NSX100R three-pole moulded-case circuit breaker (MCCB) with a magnetic-only MA trip unit rated 12.5 A at 65 °C, built for motor protection in industrial power distribution. The MA trip unit provides magnetic-only short-circuit protection (I), meaning it responds to fault currents but not to overloads — the motor starter's overload relay handles thermal protection. This coordination keeps the breaker from tripping on motor inrush while still clearing a bolted fault. ## Breaking capacity that keeps the line running Rated 200 kA Icu at 415 V AC (50/60 Hz) per IEC 60947-2, this breaker can interrupt a 200 kA prospective fault current without damage — selectivity headroom for a high-fault point in the distribution, like a motor control centre fed by a large transformer. At 690 V AC the Icu drops to 45 kA; at 525 V AC it holds 65 kA. Connection pitch 35 mm. IP40 enclosure protection, IK07 impact resistance.","metaTitle":"Schneider ComPacT NSX C10R3MA013 MCCB, 12.5 A, 200 kA","metaDescription":"Schneider Electric ComPacT NSX C10R3MA013 MCCB, 12.5 A, MA trip, 200 kA Icu at 415 V AC, motor protection, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10R3MA013","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","description":"Circuit breaker ComPacT NSX100R, 200kA at 415VAC, MA trip unit 12.5A, 3 poles 3d","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"MA","Number of slots":"5 slot(s)","Protection type":"I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"12.5 A at 65 °C","Breaking capacity":"200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX100R","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Motor protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"12.5 A at 65 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"R 200 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"0.63 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"I","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"200 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Instantaneous protection pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] Short-time protection pick-up adjustment range":"6...14 x In","[Ii] instantaneous protection pick-up adjustment range":"6...14 x In"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$11.58","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/af4991b9996ce52da10895af3dcaef9a.pdf","sourceUrl":"https://www.se.com/ae/en/product/C10R3MA013/circuit-breaker-compact-nsx100r-200ka-at-415vac-ma-trip-unit-12-5a-3-poles-3d/"},"ai":{"faq":[{"question":"What is the breaking capacity of C10R3MA013?","answer":"200 kA Icu at 415 V AC 50/60 Hz per IEC 60947-2, with lower ratings at higher voltages: 80 kA at 500 V, 65 kA at 525 V, 45 kA at 690 V."},{"question":"What is the MA trip unit for?","answer":"The MA trip unit provides magnetic-only short-circuit protection (I), designed for motor protection where the overload relay handles thermal protection and the breaker clears faults only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10R3MA013","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10R3MA013 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}