{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10S2TM080","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10S2TM080","canonicalUrl":"https://aoctrl.com/schneider/C10S2TM080","factsUrl":"https://aoctrl.com/api/mcp/products/C10S2TM080","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100S, 80 A, 2-pole, thermal-magnetic MCCB, 70 kA Icu at 415 V AC, toggle control.","salesMarkdown":"## 80 A MCCB with a breaking-capacity ladder that covers most distribution panels The Schneider Electric C10S2TM080 is a ComPacT NSX100S 2-pole MCCB rated 80 A at 40 °C with a TM-D thermal-magnetic trip unit. The TM-D provides L (overload, thermal) and I (short-circuit, magnetic) protection — the standard dual-slop curve for distribution and light motor feeder duty. The 70 mm wide, 161 mm high fixed-mount body (86 mm depth) fits backplate-mount panels with a 35 mm connection pitch. The S breaking capacity code means 70 kA Icu at 415 V AC, 100 kA at 240 V AC, and 35 kA at 525 V AC — enough headroom for most industrial distribution boards without cascading upstream. Above 40 °C the trip unit derates — the thermal element responds to ambient heat, so a panel running at 50 °C needs a higher-rated frame or forced ventilation. The 100 kA at 240 V AC covers high-fault residential or light commercial service entrances; the 35 kA at 525 V AC suits 480 V industrial systems. The 2-pole configuration (2P) protects two phases or one phase plus neutral in a single-phase or split-phase distribution. The TM-D trip unit has a fixed magnetic pickup — no interchangeable rating plugs — so the 80 A setting is permanent. ## Deployment context The IK07 impact rating (per IEC 62262) handles accidental tool drops during maintenance. Pollution degree 3 (IEC 60664-1) means it tolerates conductive dust in industrial environments without conformal coating.","metaTitle":"Schneider Electric C10S2TM080 ComPacT NSX 80A 2P MCCB, 70kA","metaDescription":"Schneider Electric C10S2TM080 ComPacT NSX100S 80A 2-pole MCCB with TM-D trip unit. 70 kA Icu at 415 V AC per IEC 60947-2. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10S2TM080","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"70 mm","Height (H)":"161 mm","description":"Circuit breaker, ComPacT NSX100S AC/DC, 70kA/415VAC, 2 poles, TMD trip unit 80A","Control type":"Toggle","Network type":"AC DC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"80 A at 40 °C","Breaking capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 250 V DC 1 pole conforming to IEC 60947-2 100 kA Icu at 500 V DC 2 poles in series conforming to IEC 60947-2 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2","Device short name":"NSX100S","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"80 A at 40 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 277 V In/2 10000 cycles at 277 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"S 70 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"8.77 W","Protected poles description":"2D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz 500 V DC","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 250 V DC conforming to IEC 60947-2 100 kA at 500 V DC conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"640 A","Long-time pick-up adjustment type Ir (thermal protection)":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/783c1194e5789a7e89415edb7f4c373c.pdf","sourceUrl":"https://www.se.com/nz/en/product/C10S2TM080/circuit-breaker-compact-nsx100s-ac-dc-70ka-415vac-2-poles-tmd-trip-unit-80a/"},"ai":{"faq":[{"question":"What is the breaking capacity of C10S2TM080 at 415 V?","answer":"70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The S breaking capacity code designates this 70 kA level at 415 V."},{"question":"What is the closest alternative to C10S2TM080 in the ComPacT NSX family?","answer":"Within the same NSX100S frame, the closest alternative would be a different trip unit rating (e.g., 63 A or 100 A TM-D) or a different breaking capacity code (H or L). The C10S2TM080 is the 80 A, 2-pole, S-breaking-capacity variant; a 3-pole version or one with an electronic Micrologic trip unit would differ in form factor and protection curve. No direct pin-compatible substitute exists — the trip rating is fixed to the breaker."},{"question":"Where can I buy C10S2TM080 and how is it quoted?","answer":"The C10S2TM080 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10S2TM080","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10S2TM080 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}