{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10V32M100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10V32M100","canonicalUrl":"https://aoctrl.com/schneider/C10V32M100","factsUrl":"https://aoctrl.com/api/mcp/products/C10V32M100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, circuit breaker, 3P, 100 A at 65 °C, 85 kA Icu at 500 V AC, MicroLogic 2.2 M electronic trip unit, motor protection.","salesMarkdown":"## Motor protection circuit breaker with MicroLogic 2.2 M trip unit It carries an 85 kA Icu breaking capacity at 500 V AC (50/60 Hz) per IEC 60947-2, which means it can safely interrupt fault currents up to that level without upstream damage — critical for high-fault installations like motor control centers. The MicroLogic 2.2 M electronic trip unit provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection, with motor tripping classes 20, 5, and 10 selectable to match the thermal curve of the motor load. The HB1 breaking capacity code (75 kA at 690 V AC) gives this breaker headroom for high-fault applications. At 500 V AC the Icu is 85 kA; at 525 V AC it's 80 kA; at 660/690 V AC it's 75 kA — all per IEC 60947-2. That means the part can be used in systems with available fault current up to those levels, simplifying selective coordination with downstream devices. The utilisation category A (non-selectivity for short-circuit) means it's intended for standalone or cascaded protection rather than full selectivity with an upstream breaker. IP40 front-face protection and IK07 impact resistance suit enclosed panel environments — not washdown zones, but fine for dry indoor switchgear. Relative humidity 0–95%. Overvoltage category III (fixed installation). Standards: EN/IEC 60947-2.","metaTitle":"Schneider Electric C10V32M100 ComPacT NSX Circuit Breaker, 1","metaDescription":"Schneider Electric C10V32M100 ComPacT NSX circuit breaker, 3P, 100 A at 65 °C, 85 kA Icu at 500 V AC. Motor protection with MicroLogic 2.2 M trip unit. Active production, sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10V32M100","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","description":"Circuit breaker ComPacT NSX100HB1, 75kA at 690VAC, MicroLogic 2.2 M trip unit 100A, 3 poles 3d","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.2 M","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 65 °C","Breaking capacity":"85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX100HB1","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Motor protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"100 A at 65 °C","Downside connection":"Front","Motor tripping class":"20 5 10","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"HB1 75 kA 690 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"4.7 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Complementary motor protection":"Phase unbalance","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"50...100 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$8.38","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a4a16cb0c2d5fcb5182dfd94de1f9a4a.pdf","sourceUrl":"https://www.se.com/ph/en/product/C10V32M100/circuit-breaker-compact-nsx100hb1-75ka-at-690vac-micrologic-2-2-m-trip-unit-100a-3-poles-3d/"},"ai":{"faq":[{"question":"Where can I buy C10V32M100 and what is the lead time?","answer":"The C10V32M100 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is C10V32M100's listed range on this component line?","answer":"The C10V32M100 belongs to the ComPacT range, specifically the ComPacT NSX series."},{"question":"What is C10V32M100's listed depth?","answer":"The depth is 86 mm."},{"question":"What compliance documentation does this brand provide for C10V32M100?","answer":"The breaker is certified to EN/IEC 60947-2. The manufacturer provides standard compliance documentation including RoHS and REACH declarations upon request through the authorized channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10V32M100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10V32M100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}