{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10W46E100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10W46E100","canonicalUrl":"https://aoctrl.com/schneider/C10W46E100","factsUrl":"https://aoctrl.com/api/mcp/products/C10W46E100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider C10W46E100 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The C10W46E100 is a Schneider ComPacT NSX molded case circuit breaker with a 100 A frame, 4 poles, and a MicroLogic 6.2 E electronic trip unit rated 100 A at 40 °C. It delivers a 100 kA ICu breaking capacity at 690 V AC, covering high-fault distribution panels, and provides LSI plus ground-fault protection with an adjustable long-time delay. Compared to the C10F3TM025, the C10W46E100 adds a fourth pole (4 vs 3), raises the breaking capacity from 85 kA to 100 kA ICu, and increases the switching current from 25 A to 100 A — the C10F3TM025 is a 3-pole 25 A unit with a fixed long-time delay, while the C10W46E100 carries an adjustable delay and ground-fault protection.","metaTitle":"Schneider C10W46E100 ComPacT NSX circuit breaker, 100 A, 4-pole, 100 kA ICu","metaDescription":"Schneider C10W46E100 ComPacT NSX molded case circuit breaker, 100 A frame, 4 poles, 100 kA ICu at 690 V AC, MicroLogic 6.2 E electronic trip unit with LSI and ground-fault protecti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$15.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d399b29952b487e9119081062c52fa8a.pdf","sourceUrl":"https://www.se.com/za/en/product/C10W46E100/circuit-breaker-compact-nsx100hb2-100ka-at-690vac-micrologic-6-2-e-trip-unit-100a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10W46E100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10W46E100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10W46E100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}