{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C114100LS","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C114100LS","canonicalUrl":"https://aoctrl.com/schneider/C114100LS","factsUrl":"https://aoctrl.com/api/mcp/products/C114100LS","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSXm 100NA, switch disconnector, 4 poles, Ith 100 A at 40 °C, 440 V AC, EverLink lugs, toggle control, IP40, IK07.","salesMarkdown":"The Schneider Electric C114100LS is a ComPacT NSXm 100NA switch disconnector, 4 poles, rated 100 A in both AC-22 and AC-23 utilisation categories at 440 V AC 50/60 Hz. It is suited for isolation per EN/IEC 60947-3, with a visible break indicator and toggle control. The 100 A thermal current (Ith) at 40 °C means it handles full-rated resistive and moderately inductive loads without derating in a 40 °C panel ambient. Rated operational current is 100 A in both AC-22 (switching mixed resistive and inductive loads, including moderate overloads) and AC-23 (switching motors or other highly inductive loads). That 100 A holds at 440 V AC — no derating needed for the voltage step. Short-time withstand (Icw) is 1500 A for 1 s or 3 s, and 335 A for 20 s, which covers downstream fault clearing coordination. Short-circuit making capacity (Icm) is 2.13 kA as a stand-alone switch-disconnector, or 150 kA with an upstream protection circuit breaker — so it can be paired with a fast-acting breaker upstream for high-fault-current installations. That puts it in the standard industrial panel category — no special creepage or clearance needed for most 400 V distribution. Fixed mounting mode, 108 mm wide, 137 mm tall, 80 mm deep — fits a standard 4-pole disconnector footprint. Connection pitch 27 mm, terminals accept EverLink lugs: 2.5…70 mm² flexible copper, or 2.5…95 mm² rigid/stranded aluminium/copper. IP40 front face, IK07 impact resistance. Operating temperature -25…70 °C, storage -50…85 °C.","metaTitle":"Schneider Electric C114100LS ComPacT NSXm 100NA Switch Disco","metaDescription":"Schneider Electric C114100LS switch disconnector, ComPacT NSXm 100NA, 4 poles, 100 A AC-22/AC-23, 440 V AC. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","Depth (D)":"80 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-3","Width (W)":"108 mm","Height (H)":"137 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSXm","Mounting mode":"Fixed","Visible break":"No","lifecycle_stage":"current","Connection pitch":"27 mm","Mounting support":"35 mm symmetrical DIN rail Backplate","Pollution degree":"3 conforming to IEC 60664-1","Device short name":"NSXm 100NA","Poles description":"4P","Device application":"Distribution","Utilisation category":"AC-22A AC-23A","Electrical durability":"AC-22A: 20000 cycles 440 V AC 50/60 Hz Ie/2 AC-23A: 20000 cycles 440 V AC 50/60 Hz Ie/2 AC-22A: 10000 cycles 440 V AC 50/60 Hz Ie AC-23A: 10000 cycles 440 V AC 50/60 Hz Ie","Mechanical durability":"20000 cycles","Breaking capacity code":"NA","Connections - terminals":"1 Everlink lug wire size 2.5...70 mm², flexible copper 1 Everlink lug wire size 2.5...95 mm², rigid or stranded aluminium/copper","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN/IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","[Ie] rated operational current":"AC-23: 100 A AC 50/60 Hz AC-22: 100 A AC 50/60 Hz","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1500 A during 1 s 1500 A during 3 s 335 A during 20 s","[Icm] rated short-circuit making capacity":"2.13 kA switch-disconnector alone 150 kA with upstream protection circuit breaker","[Ith] conventional free air thermal current":"100 A at 40 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$264.70","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/df6cacc6a12d665a167d84c3fb6dca7c.pdf","sourceUrl":"https://www.se.com/au/en/product/C114100LS/switch-disconnector-compact-nsxm-100na-4-poles-thermal-current-ith-100a-everlink-lugs/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C114100LS/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C114100LS?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is C114100LS used for?","answer":"It is a switch disconnector for distribution applications — isolating and switching loads up to 100 A at 440 V AC in AC-22 (mixed loads) or AC-23 (motor/inductive) circuits. Suited for isolation per EN/IEC 60947-3, with a visible break indicator."},{"question":"What compliance documentation does Schneider provide for C114100LS?","answer":"The part is certified to EN/IEC 60947-1 and EN/IEC 60947-3. It carries IP40 and IK07 protection ratings, and is rated for pollution degree 3 per IEC 60664-1. Electrical shock protection class II. For specific RoHS/REACH/UL documentation, request the compliance certificate with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C114100LS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C114100LS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}