{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C11E44V050L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C11E44V050L","canonicalUrl":"https://aoctrl.com/schneider/C11E44V050L","factsUrl":"https://aoctrl.com/api/mcp/products/C11E44V050L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSXm, MCCB, 50 A, 4P, 16 kA 415 V AC, electronic MicroLogic 4.1 trip unit, integrated earth-leakage protection, grey (RAL 7016).","salesMarkdown":"The Schneider Electric C11E44V050L is a ComPacT NSXm moulded-case circuit breaker rated 50 A at 40 °C, four-pole (4P), with a breaking capacity of 16 kA at 415 V AC — performance level E. It carries an electronic MicroLogic 4.1 trip unit that provides adjustable thermal-magnetic protection curves and integrated earth-leakage protection (Vigi module) with selectable sensitivity from 30 mA to 5 A for class A or class AC faults. It handles 50/60 Hz networks, mounts on a backplate in horizontal or vertical orientation, and uses front-front connection via Everlink lugs (accepting 2.5–70 mm² fine stranded copper or 2.5–95 mm² rigid/stranded aluminium/copper). No official successor exists because this part is active. If your BOM calls for the C11E44V050L, the MicroLogic 4.1 trip unit and the Vigi earth-leakage module are factory-integrated — no separate ordering of the trip unit and Vigi add-on. This is the single-order-code path for a 50 A 4P MCCB with adjustable earth-leakage in the ComPacT NSXm family. Mounts on a backplate — not DIN rail — so plan for a drilled panel or a mounting plate with the 108 mm width × 144 mm height footprint (12-module pitch at 9 mm per module). IP40 enclosure protection (IK07 impact resistance) means it's suited for indoor panel installation where dust and tool drops are the main concern — not washdown environments. The grey RAL 7016 housing is the standard industrial finish across the ComPacT range. Derate for higher ambient temperatures per IEC 60947-2; the electronic trip unit compensates automatically for ambient changes, but the conductor sizing still needs to follow the 50 A mark. Earth-leakage sensitivity is field-selectable via the Vigi module: choose 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, or 5 A for class A or class AC residual currents. Class A detects pulsating DC residuals — critical for circuits with electronic loads (VFDs, switched-mode supplies) that generate half-wave fault currents. Class AC covers sinusoidal AC only. Set the threshold to match the downstream protection coordination. Mechanical durability is 20,000 cycles; electrical durability is 20,000 cycles at 440 V at rated current (In) and 10,000 cycles at 440 V at twice rated current (In/2). For a distribution breaker used infrequently (a few operations per year), this is effectively a lifetime rating. For frequent switching applications (like motor control), the electrical endurance at In/2 is the limiting curve.","metaTitle":"Schneider Electric C11E44V050L ComPacT NSXm 50A 4P MCCB, 16k","metaDescription":"Schneider Electric C11E44V050L ComPacT NSXm MCCB. 50A rated current, 4 poles, 16 kA breaking capacity at 415 V AC. Electronic MicroLogic 4.1 trip unit with integrated earth-leakage","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Grey (RAL 7016)","Depth":"80 mm","Width":"108 mm","Height":"144 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm with spreaders 27 mm without spreaders","Trip Unit Type":"Electronic","Safety Category":"E 16 kA 415 V AC","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$649.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c59520505d4b5c1d2dc0a598b2c9d5a.pdf","sourceUrl":"https://www.se.com/th/en/product/C11E44V050L/circuit-breaker-compact-nsxm-63e-16ka-415vac-4-poles-micrologic-4-1-trip-unit-50a-everlink-lugs/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C11E44V050L/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C11E44V050L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C11E44V050L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}