{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C11E44V100L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C11E44V100L","canonicalUrl":"https://aoctrl.com/schneider/C11E44V100L","factsUrl":"https://aoctrl.com/api/mcp/products/C11E44V100L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSXm, MCCB, 4P, 100 A at 40 °C, 16 kA at 415 V AC, MicroLogic 4.1 electronic trip unit, integrated earth-leakage protection, EN/IEC 60947-2.","salesMarkdown":"The C11E44V100L is a Schneider Electric ComPacT NSXm moulded-case circuit breaker (MCCB) in the 160E frame size, 4-pole (4P) configuration, with a MicroLogic 4.1 electronic trip unit rated at 100 A at 40 °C. The integrated earth-leakage protection covers adjustable sensitivities from 30 mA to 5 A for both class A and class AC faults. If your enclosure runs hotter, you derate; the electronic MicroLogic 4.1 trip unit includes thermal memory that tracks heat buildup for 20 minutes before and after a trip event, so it won't reclose into a still-hot conductor. In a 415 V distribution board, that SCCR covers most secondary-side faults downstream of a typical 1000 kVA transformer. Integrated earth-leakage protection means you do not need a separate RCCB or Vigi module. The MicroLogic 4.1 trip unit senses residual currents and offers selectable sensitivity from 30 mA (personnel protection) up to 5 A (equipment protection), for both class A (pulsating DC) and class AC (sinusoidal AC) fault types. That saves a module width in the panel. The 4-pole unit occupies 12 module pitches of 9 mm — about 108 mm wide. Connection pitch is 35 mm with spreaders, 27 mm without. Everlink lug terminals accept copper from 2.5 to 95 mm² (fine stranded) and aluminium up to 95 mm², with front-facing connections for both line and load sides. IP40 protection (finger-safe, no water ingress) and IK07 impact resistance suit it for enclosed distribution boards indoors. The grey (RAL 7016) finish is standard for Schneider's ComPacT range.","metaTitle":"Schneider Electric C11E44V100L ComPacT NSXm MCCB, 100 A, 16","metaDescription":"Schneider Electric C11E44V100L ComPacT NSXm MCCB, 4P, 100 A at 40 °C, 16 kA at 415 V AC, MicroLogic 4.1 electronic trip unit with integrated earth-leakage protection. EN/IEC 60947-","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Colour":"Grey (RAL 7016)","Depth (D)":"80 mm","Standards":"EN/IEC 60947-2","Width (W)":"108 mm","Height (H)":"144 mm","9 Mm Pitches":"12 module","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSXm","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 4.1","lifecycle_stage":"current","Connection pitch":"35 mm with spreaders 27 mm without spreaders","Local signalling":"Flag (green) for presence of auxiliary contacts","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 40 °C","Device short name":"NSXm 160E","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Performance level":"E 16 kA 415 V AC","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"2000 m without derating 5000 m with derating","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Connection terminals":"1 Everlink lug wire size 2.5...70 mm², fine stranded copper 1 Everlink lug wire size 2.5...95 mm², rigid or stranded aluminium/copper","Overvoltage category":"IV","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In","Mechanical durability":"20000 cycles","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Power dissipation per pole":"4.8 W","Neutral protection settings":"1 x Ir (4D)","Protected poles description":"4D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Class A Class AC","Trip unit protection functions":"LSoIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"200 s at 1.5 x Ir 8 s at 6 x Ir 5 s at 7.2 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"40...100 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[Δt] Earth-leakage protection time delay adjustment range":"0 ms 60 ms 150 ms 500 ms 1000 ms","[IΔn] earth-leakage protection sensitivity adjustment range":"30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$649.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2fd07e04111aa3c194ca011af6a8e345.pdf","sourceUrl":"https://www.se.com/id/en/product/C11E44V100L/circuit-breaker-compact-nsxm-e-16ka-at-415vac-4-poles-4d-100a-rating-micrologic-4-1-trip-unit-everlink-connectors/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C11E44V100L/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C11E44V100L?","answer":"16 kA at 415 V AC, performance level E, per EN/IEC 60947-2."},{"question":"Does this MCCB include earth-leakage protection?","answer":"Yes, the MicroLogic 4.1 trip unit has integrated earth-leakage protection with adjustable sensitivity from 30 mA to 5 A for both class A and class AC faults."},{"question":"What terminals does the C11E44V100L use?","answer":"Everlink lug terminals accepting 2.5–95 mm² copper (fine stranded) or aluminium, with front-facing connections."},{"question":"Where can I buy C11E44V100L?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C11E44V100L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C11E44V100L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}