{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C125N45AFM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C125N45AFM","canonicalUrl":"https://aoctrl.com/schneider/C125N45AFM","factsUrl":"https://aoctrl.com/api/mcp/products/C125N45AFM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C125N45AFM, 4P molded case circuit breaker, 1250 A at 50 °C, MicroLogic 5.0 A electronic trip unit, 50 kA Icu at 415 V AC, fixed mounting, IP40.","salesMarkdown":"The Schneider Electric C125N45AFM is a ComPacT NS new generation molded case circuit breaker (MCCB) rated 1250 A at 50 °C, in a 4-pole (4P) fixed-mount configuration with a MicroLogic 5.0 A electronic trip unit. It's built for distribution duty per EN/IEC 60947-2, meaning it protects feeders and main switchboards in commercial and industrial power systems — the kind of install where you need selectivity and coordination downstream, not just a simple branch breaker. Breaking capacity is the headline here: 85 kA Icu at 240 V AC, 50 kA at 415 V, 40 kA at 525 V, and 30 kA at 690 V. That S function is what separates a distribution breaker from a simple thermal-magnetic — it lets you coordinate with downstream breakers so only the faulted branch clears, not the whole board. The thermal memory holds for 20 minutes, which matters if you're resetting after a hot overload on a motor feeder. The trip unit includes an ammeter (type of measurement: ammeter) and an LCD display for reading load current locally. Four red LEDs flag fault types; one yellow LED indicates an overload condition. That's useful for an electrician walking the board — they can see at a glance whether the trip was overload or short-circuit without hooking up a laptop. Fixed mounting on a backplate, 280 mm wide by 327 mm tall by 147 mm deep. Connection pitch is 70 mm, and both upside and downside connections are front-facing — that means you can land cables without needing rear access, which is standard for most switchboards but worth confirming if you're retrofitting into a tight enclosure. Manually operated (no motor operator included), with the neutral on the left side of the 4-pole block. Mechanical durability is 10,000 cycles; electrical durability ranges from 2,000 cycles at full-rated 690 V to 5,000 cycles at half-rated 440 V. That's typical for a fixed-mount distribution breaker — it's not designed for frequent switching like a contactor, but it handles routine isolation and infrequent fault clearing without issue. The ComPacT NS new generation family is widely stocked, but a 1250 A frame is a larger unit — lead time can vary with demand, so a firm RFQ is the right next step if you're planning a board build.","metaTitle":"Schneider Electric C125N45AFM ComPacT NS, 1250 A, 50 kA at 4","metaDescription":"Schneider Electric C125N45AFM ComPacT NS new generation molded case circuit breaker, 1250 A, 4P, MicroLogic 5.0 A trip unit, 50 kA breaking capacity at 415 V AC. Active production,","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"147 mm","Poles":"4P","Width":"280 mm","Height":"327 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Manually operated","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"70 mm","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Utilization Category":"Category B","Connection Surface Top":"Front","Electrical Life Cycles":"2000 cycles at 690 V In 3000 cycles at 690 V In/2 4000 cycles at 440 V In 5000 cycles at 440 V In/2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/22cd1764c43289f0095072b88f5d85b1.pdf","sourceUrl":"https://www.se.com/ie/en/product/C125N45AFM/circuit-breaker-compact-ns1250n-50ka-at-415vac-4p-fixed-manually-operated-micrologic-5-0a-control-unit-1250a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C125N45AFM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C125N45AFM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C125N45AFM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}