{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C12H34V160L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C12H34V160L","canonicalUrl":"https://aoctrl.com/schneider/C12H34V160L","factsUrl":"https://aoctrl.com/api/mcp/products/C12H34V160L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSXm, C12H34V160L, 160 A, 3P, earth leakage circuit breaker with MicroLogic 4.1 electronic trip, 70 kA at 415 V AC, grey (RAL 7016).","salesMarkdown":"## What this 160 A ELCB brings to a distribution board The C12H34V160L is a Schneider Electric ComPacT NSXm earth leakage circuit breaker, 3-pole, rated 160 A at 40 °C with a MicroLogic 4.1 electronic trip unit. Integrated earth-leakage protection with selectable sensitivity (30 mA to 5 A, class A and AC) eliminates a separate RCCB module — one device covers both overcurrent and ground-fault protection. Backplate-mounted, 9-module pitch (108 mm wide, 144 mm high, 80 mm deep). Front connections top and bottom. Accepts Everlink lugs: 2.5–70 mm² fine stranded copper or 2.5–95 mm² rigid stranded aluminium/copper. Connection pitch is 35 mm with spreaders, 27 mm without — plan your busbar or cable-fan layout accordingly. Pollution degree 3 (IEC 60664-1) and overvoltage category IV — this is the standard spec for industrial distribution boards where conductive pollution or transient overvoltages are expected. IP40 front face, IK07 impact resistance. The grey RAL 7016 enclosure is the standard ComPacT colour. ## Durability and environmental range Rated for 20,000 mechanical cycles and 20,000 electrical cycles at 440 V In/2 (10,000 at 440 V In). Operating altitude 2000 m without derating, up to 5000 m with derating. Relative humidity 0–95%. Network frequency 50/60 Hz. Utilisation category A (non-discriminative, no intentional short-time delay).","metaTitle":"Schneider Electric C12H34V160L ComPacT NSXm 160A 3P ELCB, 70","metaDescription":"Schneider Electric C12H34V160L ComPacT NSXm 160A 3-pole earth leakage circuit breaker with MicroLogic 4.1 electronic trip, 70 kA at 415 V AC. Current lifecycle stage. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Colour":"Grey (RAL 7016)","Depth (D)":"80 mm","Standards":"EN/IEC 60947-2","Width (W)":"108 mm","Height (H)":"144 mm","9 Mm Pitches":"9 module","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSXm","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 4.1","lifecycle_stage":"current","Connection pitch":"35 mm with spreaders 27 mm without spreaders","Local signalling":"Flag (green) for presence of auxiliary contacts","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"160 A at 40 °C","Device short name":"NSXm 160H","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Performance level":"H 70 kA 415 V AC","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"2000 m without derating 5000 m with derating","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Connection terminals":"1 Everlink lug wire size 2.5...70 mm², fine stranded copper 1 Everlink lug wire size 2.5...95 mm², rigid or stranded aluminium/copper","Overvoltage category":"IV","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In","Mechanical durability":"20000 cycles","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Power dissipation per pole":"12.3 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Class A Class AC","Trip unit protection functions":"LSoIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","Number of slots for electrical auxiliaries":"1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"200 s at 1.5 x Ir 8 s at 6 x Ir 5 s at 7.2 x Ir","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"63...160 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ics] rated service short-circuit breaking capacity":"100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Icu] rated ultimate short-circuit breaking capacity":"100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"2000 A","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[Δt] Earth-leakage protection time delay adjustment range":"0 ms 60 ms 150 ms 500 ms 1000 ms","[IΔn] earth-leakage protection sensitivity adjustment range":"30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,979.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4428e5f70c4498ff1200af7dcfb3e4c9.pdf","sourceUrl":"https://www.se.com/vn/en/product/C12H34V160L/circuit-breaker-compact-nsxm-160h-70ka-415vac-3-poles-micrologic-4-1-trip-unit-160a-everlink-lugs/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C12H34V160L/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to C12H34V160L in the ComPacT family?","answer":"Within the same NSXm frame, the closest sibling would be a 160 A 3P version without integrated earth-leakage (a standard MCCB) if ground-fault protection isn't needed. The earth-leakage variant with a different sensitivity range or class (e.g., class A only, or a fixed 300 mA) would be the parametric alternative — same frame, same breaking capacity, same footprint. No pin-compatible drop-in exists outside the Schneider ComPacT NSXm family."},{"question":"Who supplies C12H34V160L and how is it quoted for volume purchases?","answer":"We source this part through independent distribution channels. Submit an RFQ with your target quantity and delivery window; we'll confirm availability and provide current pricing at quote time. No minimum order quantity restrictions apply."},{"question":"What compliance documentation does Schneider provide for C12H34V160L?","answer":"The part is certified to EN/IEC 60947-2. Pollution degree 3 per IEC 60664-1 and overvoltage category IV are documented. RoHS and REACH declarations are available from Schneider Electric's documentation portal for the ComPacT NSXm series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C12H34V160L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C12H34V160L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}