{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C160H360FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C160H360FM","canonicalUrl":"https://aoctrl.com/schneider/C160H360FM","factsUrl":"https://aoctrl.com/api/mcp/products/C160H360FM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C160H360FM, 3P 1600 A circuit breaker, MicroLogic 6.0 electronic trip unit, 70 kA Icu at 415 V AC, fixed mount.","salesMarkdown":"The Schneider Electric C160H360FM is a ComPacT NS new generation 3-pole fixed-mount circuit breaker with a MicroLogic 6.0 electronic trip unit rated at 1600 A at 50 °C. The breaker is part of the ComPacT NS630b…1600 new generation range. Breaking capacity is 85 kA Icu at 220/240 V AC, 70 kA Icu at 380/415 V AC, 65 kA Icu at 440 V AC, 50 kA Icu at 500/525 V AC, and 42 kA Icu at 660/690 V AC — all at 50/60 Hz per IEC 60947-2. The MicroLogic 6.0 trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection curves — all electronic, adjustable. The thermal memory is 20 minutes, so the trip unit remembers prior heating events and shortens the time-to-trip on a reclose, which matters for motor or transformer inrush that can follow a fast reclosure. Power losses are 74 W at rated current — that heat has to leave the enclosure. The breaker is IP40 (finger-safe, no water ingress) and IK07 (2 J impact resistance), so it is suited for indoor switchboard or panel mounting on a backplate. Front connections top and bottom, 70 mm phase pitch, so it fits standard busbar and cable layouts. ## Integration and deployment Mounting is fixed on a backplate — no DIN-rail adapter, so plan for a drilled or tapped panel. Dimensions are 327 mm high × 210 mm wide × 147 mm deep, which is a standard ComPacT NS footprint. The 70 mm phase pitch matches the existing busbar systems in most LV switchboards. Front connections top and bottom simplify busbar routing and cable glanding. Local signalling uses four red LEDs for fault indication (one each for L, S, I, G trip events) and one yellow LED for overload pre-alarm — useful for a technician walking the panel to identify which protection curve caused the trip without plugging in a laptop. Relative humidity range is 0–95 %. These environmental ratings mean it is fit for industrial switchrooms, not just climate-controlled data centres.","metaTitle":"Schneider Electric C160H360FM ComPacT NS, 1600 A, 70 kA 415","metaDescription":"Schneider Electric C160H360FM ComPacT NS new generation circuit breaker, 1600 A trip unit, 70 kA Icu at 415 V AC, MicroLogic 6.0 electronic trip unit. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","title":"C160H360FM","Depth (D)":"147 mm","Standards":"EN/IEC 60947-2","Width (W)":"210 mm","Height (H)":"327 mm","description":"Circuit breaker, ComPacT NS1600H, 70kA at 415VAC, 3P, fixed, manually operated, MicroLogic 6.0 control unit, 1600A","Control type":"Manually operated","Network type":"AC","Power losses":"74 W","Product name":"ComPacT NS new generation","Mounting mode":"Fixed","Thermal memory":"20 mn","Trip unit name":"MicroLogic 6.0","Number of poles":"3P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Connection pitch":"70 mm","Local signalling":"4 LEDs (red) for fault indication 1 LED (yellow) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"ComPacT NS630b...1600 new generation","Trip unit rating":"1600 A at 50 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Network frequency":"50/60 Hz","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"1600 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2","Mechanical durability":"10000 cycles","Breaking capacity code":"H 70 kA 415 V AC","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Protected poles description":"3D","Auxiliary contact composition":"1 NO/NC","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","[Icw] rated short-time withstand current":"19.2 kA 1 s conforming to IEC 60947-2","[Ig] ground-fault pick-up adjustment range":"0.3...1 x In for In 0.2...1 x In for 400 A < In < 1250 A 500...1200 A for In >= 1250 A","Long-time protection delay adjustment type tr":"Adjustable 9 settings","[tg] Ground-fault time delay adjustment range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Short-time protection delay adjustment type tsd":"Adjustable","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ii] instantaneous protection pick-up adjustment range":"Off 2...15 x In","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/26a004ee907b072f778288b8ef79c3f8.pdf","sourceUrl":"https://www.se.com/vn/en/product/C160H360FM/circuit-breaker-compact-ns1600h-70ka-at-415vac-3p-fixed-manually-operated-micrologic-6-0-control-unit-1600a/"},"ai":{"faq":[{"question":"Who supplies C160H360FM and how is it quoted for volume purchases?","answer":"We source C160H360FM through independent distribution channels and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is C160H360FM's breaking capacity at 415 V?","answer":"At 380/415 V AC 50/60 Hz, the C160H360FM is rated 70 kA Icu per IEC 60947-2, which is the 'H' breaking capacity code."},{"question":"What protection curves does the MicroLogic 6.0 trip unit provide?","answer":"The MicroLogic 6.0 provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection — all adjustable electronic curves."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C160H360FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C160H360FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}