{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C160N42AFM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C160N42AFM","canonicalUrl":"https://aoctrl.com/schneider/C160N42AFM","factsUrl":"https://aoctrl.com/api/mcp/products/C160N42AFM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C160N42AFM, 4-pole MCCB, 1600 A at 50 °C, MicroLogic 2.0 A electronic trip unit, 50 kA Icu at 415 V AC, fixed mount, front connection.","salesMarkdown":"The Schneider Electric C160N42AFM is a ComPacT NS new generation 4-pole moulded-case circuit breaker rated 1600 A at 50 °C, fitted with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection. It is a manually operated distribution breaker built to EN/IEC 60947-2, Category B — meaning it is intended for use in distribution panels where selectivity with downstream breakers is required, not just motor-circuit isolation. ## Breaking capacity — what the N code means for your system The N breaking capacity code (50 kA at 415 V AC) tells you this breaker can interrupt 50,000 A of prospective fault current at 380–415 V, 50/60 Hz. At 220–240 V it handles 85 kA Icu; at 690 V it still clears 30 kA. The full Icu curve across voltages means you can apply this breaker upstream without worrying about cascading failure at the lower fault levels common on long cable runs. Fixed-mount design on a backplate, front-connected both top and bottom. The 280 mm width, 327 mm height, and 147 mm depth fit standard switchboard cubicle compartments — plan for a 70 mm connection pitch between phases. The LCD display on the MicroLogic 2.0 A trip unit gives local ammeter readout and fault indication via four red LEDs plus a yellow overload LED — useful for a quick visual check during commissioning or after a trip event. ## Electrical durability and thermal memory Rated for 1000 electrical cycles at full rated current and 690 V, and 10,000 mechanical cycles — that is a standard durability envelope for a fixed-mount distribution breaker of this size. The 20-minute thermal memory in the MicroLogic 2.0 A trip unit means the breaker remembers the thermal history of the last overload event for 20 minutes after the current drops below the pickup threshold, which prevents nuisance re-closing on a still-hot conductor.","metaTitle":"Schneider Electric C160N42AFM ComPacT NS 1600A, 4P, 50kA 415","metaDescription":"Schneider Electric C160N42AFM ComPacT NS new generation MCCB. 1600A at 50°C, 4P, MicroLogic 2.0 A trip unit, 50 kA Icu at 415 V AC. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"147 mm","Poles":"4P","Width":"280 mm","Height":"327 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Manually operated","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"70 mm","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Utilization Category":"Category B","Connection Surface Top":"Front","Electrical Life Cycles":"1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1261d6822bb0523f1afaaf2ea970093c.pdf","sourceUrl":"https://www.se.com/vn/en/product/C160N42AFM/circuit-breaker-compact-ns1600n-50ka-at-415vac-4p-fixed-manually-operated-micrologic-2-0a-control-unit-1600a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C160N42AFM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C160N42AFM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C160N42AFM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}