{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1636M150","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1636M150","canonicalUrl":"https://aoctrl.com/schneider/C1636M150","factsUrl":"https://aoctrl.com/api/mcp/products/C1636M150","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, MicroLogic 6.2 E-M electronic trip unit, 150 A at 65 °C, 3P, LSIG protection, LCD display, EN/IEC 60947-2.","salesMarkdown":"The C1636M150 is a MicroLogic 6.2 E-M electronic trip unit for the ComPacT NSX100...250 molded-case circuit breaker platform. It is rated 150 A at 65 °C and carries LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — making it a motor-protection trip unit with adjustable pickup and delay settings. This is a 3-pole unit for fixed-mount circuit breakers, with an LCD display that shows energy metering, protection and alarm settings, time-stamped events, and maintenance indicators. The trip unit technology is electronic, so it offers adjustable long-time pickup from 70 to 150 A and selectable motor tripping classes 5, 10, 20, or 30. The class choice directly affects how long the motor can ride through a stall or protracted start — class 10 is the standard for general-purpose motors; class 20 or 30 for high-inertia loads like fans or centrifuges. The ComPacT NSX platform is a modular MCCB family for distribution and motor control in industrial panels. The MicroLogic 6.2 E-M is specifically designed for motor protection, with complementary functions like protracted starting time, stalled rotor, current unbalance, and underload detection.","metaTitle":"Schneider Electric C1636M150 ComPacT NSX MicroLogic 6.2 E-M","metaDescription":"Schneider Electric C1636M150 MicroLogic 6.2 E-M electronic trip unit for ComPacT NSX motor protection. 150 A at 65 °C, LSIG protection, LCD display. EN/IEC 60947-2. Available to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","title":"C1636M150","Standards":"EN/IEC 60947-2","description":"trip unit MicroLogic 6.2 EM for ComPacT NSX 160/250 circuit breakers, electronic, rating 150 A, 3 poles 3d","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX100...250","Trip unit rating":"150 A at 65 °C","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Motor","Type of measurement":"Energy meter","Motor tripping class":"10 30 5 20","Trip unit technology":"Electronic","Communication of data":"Energy metering Protection and alarm settings Time-stamped histories and event tables Instantaneous and demand values Maintenance indicators Demand current and power Power quality Maximeters/minimeters","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Electrical data recording":"Maintenance indicators","Product or component type":"Trip unit","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","Complementary motor protection":"Protracted starting time Stalled rotor Current unbalance Underload","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30 38 s at 6 x Ir for trip class 30 30 s at 7.2 x Ir for trip class 30","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable","[Ir] long-time protection pick-up adjustment range":"70...150 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for In = 50 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"2250 A","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$364.10 – $1,058.56","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/655e4ca1d3b33cf69bf3cfef4f71abff.pdf","sourceUrl":"https://www.se.com/hk/en/product/C1636M150/trip-unit-micrologic-6-2-em-for-compact-nsx-160-250-circuit-breakers-electronic-rating-150-a-3-poles-3d/"},"ai":{"faq":[{"question":"What are the key protection functions of the MicroLogic 6.2 E-M?","answer":"The MicroLogic 6.2 E-M provides LSIG protection: long-time overload (L), short-time short-circuit with fixed delay (S), instantaneous short-circuit (I), and ground-fault (G). It also includes motor-specific protections for protracted starting, stalled rotor, current unbalance, and underload."},{"question":"What motor tripping classes does this trip unit support?","answer":"It supports selectable tripping classes 5, 10, 20, and 30. Class 10 is typical for standard motors; class 20 or 30 for high-inertia loads."},{"question":"Where can I buy C1636M150 and how is it quoted?","answer":"The C1636M150 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1636M150","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1636M150 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}