{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C16F1TM160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C16F1TM160","canonicalUrl":"https://aoctrl.com/schneider/C16F1TM160","factsUrl":"https://aoctrl.com/api/mcp/products/C16F1TM160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX160F, C16F1TM160, 1-pole thermal-magnetic circuit breaker, 160 A, 18 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"The C16F1TM160 is a Schneider Electric ComPacT NSX160F fixed-mount circuit breaker, 1-pole, with a TM-D thermal-magnetic trip unit rated 160 A at 40 °C. The 36 kA Icu at 250 V DC (1 pole) covers DC distribution panels where fault currents can be higher. The thermal-magnetic trip provides overload (L) and short-circuit (I) protection in one unit; no separate ground-fault module is included (earth-leakage protection is without). Fixed backplate mounting, 35 mm width per pole, 161 mm height, 86 mm depth. Horizontal or vertical orientation is acceptable; flat-on-back mounting is standard. Listed as current production (active lifecycle stage).","metaTitle":"Schneider Electric C16F1TM160 ComPacT NSX160F, 160A 1P Therm","metaDescription":"Schneider Electric C16F1TM160 ComPacT NSX160F circuit breaker, 160A thermal-magnetic trip unit, 18kA Icu at 240V AC, 1-pole, EN/IEC 60947-2. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C16F1TM160","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"35 mm","Height (H)":"161 mm","description":"Circuit breaker, ComPacT NSX160F AC/DC, 18kA/240VAC, 1 pole, TMD trip unit 160A","Control type":"Toggle","Network type":"AC DC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"160 A at 40 °C","Breaking capacity":"18 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC 1 pole conforming to IEC 60947-2","Device short name":"NSX160F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 277 V In/2 10000 cycles at 277 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"F 18 kA 240 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"13.95 W","Protected poles description":"1D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LI","[Ue] rated operational voltage":"277 V AC 50/60 Hz 250 V DC","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"18 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 250 V DC conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"1250 A","Long-time pick-up adjustment type Ir (thermal protection)":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8e2e3bc3b94292bf8062ea76eed9c6bd.pdf","sourceUrl":"https://www.se.com/th/en/product/C16F1TM160/circuit-breaker-compact-nsx160f-ac-dc-18ka-240vac-1-pole-tmd-trip-unit-160a/"},"ai":{"faq":[{"question":"What are the key ratings for C16F1TM160?","answer":"160 A thermal-magnetic trip unit (TM-D), 18 kA Icu at 240 V AC, 36 kA Icu at 250 V DC (1 pole), 1-pole, EN/IEC 60947-2. Suitable for isolation per that standard."},{"question":"What compliance documentation does this brand provide for C16F1TM160?","answer":"The breaker is certified to EN/IEC 60947-2. The manufacturer provides standard compliance documentation including RoHS and REACH declarations upon request through the RFQ process."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C16F1TM160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C16F1TM160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}