{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C16N42D160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C16N42D160","canonicalUrl":"https://aoctrl.com/schneider/C16N42D160","factsUrl":"https://aoctrl.com/api/mcp/products/C16N42D160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, NSX160N, circuit breaker, 160 A, 90 kA Icu at 240 V AC, 4 poles, MicroLogic 2.2 electronic trip unit.","salesMarkdown":"The Schneider Electric C16N42D160 is a ComPacT NSX160N moulded case circuit breaker rated 160 A at 40 °C, 4 poles, with a MicroLogic 2.2 electronic trip unit. It is designed for distribution applications and carries a 90 kA Icu breaking capacity at 240 V AC (50/60 Hz) per IEC 60947-2, stepping down to 50 kA at 415 V and 10 kA at 690 V. The N breaking capacity code means 50 kA at 415 V AC, which is the standard rating for this frame size in most panelboard and switchboard installations. It is electronic, not thermal-magnetic, so it holds calibration better across ambient temperature swings and offers a 20-minute thermal memory before and after tripping — meaning if a downstream fault clears and the breaker resets, the memory prevents immediate re-trip from residual heat, which is useful on motor-starting or welding circuits. The 90 kA Icu at 240 V AC is the maximum interrupting rating; at typical 480 V industrial supply the breaker is rated 50 kA (per UL 60947-4-1) or 50 kA at 380/415 V AC per IEC. That is sufficient for most low-voltage distribution boards with a transformer impedance of 5–6% and a fault current under 50 kA. The utilisation category is A, meaning it is not intended for frequent switching of motor loads under load; use a contactor for that duty. Neutral is on the left. IP40 front face; IK07 impact rating.","metaTitle":"Schneider Electric C16N42D160 ComPacT NSX160N, 160 A, 90 kA,","metaDescription":"Schneider Electric C16N42D160 ComPacT NSX160N circuit breaker, 160 A, 90 kA Icu at 240 V AC, 4 poles, MicroLogic 2.2 electronic trip unit. Active production, sourced to order. Quot","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In","Mechanical Life Cycles":"40000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$522.84 – $1,404.54","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5d6a215f42e3de5db2ae15015fd16b2b.pdf","sourceUrl":"https://www.se.com/au/en/product/C16N42D160/circuit-breaker-compact-nsx160n-50ka-415vac-4-poles-micrologic-2-2-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C16N42D160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C16N42D160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C16N42D160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}