{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C16N44V100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C16N44V100","canonicalUrl":"https://aoctrl.com/schneider/C16N44V100","factsUrl":"https://aoctrl.com/api/mcp/products/C16N44V100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, C16N44V100, 4-pole MCCB with MicroLogic 4.2 electronic trip unit, 100 A rating, 50 kA breaking capacity at 415 V AC.","salesMarkdown":"The Schneider Electric C16N44V100 is a ComPacT NSX160N moulded-case circuit breaker — a 4-pole, 100 A frame with an electronic MicroLogic 4.2 trip unit. ## Trip unit and protection logic The MicroLogic 4.2 is an electronic trip unit that provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage) protection. The earth-leakage protection is integrated into the breaker — no external module needed. A 20-minute thermal memory means the breaker remembers a prior overload event and will trip faster on a reclose into a still-hot conductor, which is useful for motor or transformer feeders that see repeated starts. ## Breaking capacity across voltages The C16N44V100 is rated per EN/IEC 60947-2 with the following Icu: 90 kA at 220/240 V AC, 50 kA at 380/415 V AC, 50 kA at 440 V AC, 36 kA at 500 V AC, 35 kA at 525 V AC, and 10 kA at 660/690 V AC. It also carries UL 60947-4-1 ratings: 85 kA at 240 V AC, 50 kA at 480 V AC, and 10 kA at 600 V AC. The utilisation category is A — not intended for current-limiting applications, but suitable for general distribution and feeder protection where selectivity with downstream breakers is designed in. ## Physical fit and mounting Mounts on a backplate in horizontal or vertical orientation, flat on the back. Front connections on both upside and downside. Connection pitch is 35 mm. Neutral is on the left. IP40 protection — suitable for indoor panel installation; IK07 impact resistance. ## Durability and operational life Mechanical durability is 40,000 cycles. Electrical durability varies by load: 40,000 cycles at 440 V at half rated current (In/2), 20,000 cycles at 440 V at full In, 15,000 cycles at 690 V at In/2, and 7,500 cycles at 690 V at full In. These numbers matter for a breaker that sees frequent switching — like a main disconnect on a machine that cycles every shift.","metaTitle":"Schneider Electric C16N44V100 ComPacT NSX160N, 100A, 50kA 41","metaDescription":"Schneider Electric C16N44V100 ComPacT NSX160N MCCB. 100A, 4P, MicroLogic 4.2 electronic trip. 50kA Icu at 415V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In","Mechanical Life Cycles":"40000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,221.79 – $2,527.20","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/23169506298c1ac338715b6ede24ecbd.pdf","sourceUrl":"https://www.se.com/th/en/product/C16N44V100/circuit-breaker-compact-nsx160n-50ka-415vac-4-poles-micrologic-vigi-4-2-trip-unit-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C16N44V100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C16N44V100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C16N44V100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}