{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C16N47E100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C16N47E100","canonicalUrl":"https://aoctrl.com/schneider/C16N47E100","factsUrl":"https://aoctrl.com/api/mcp/products/C16N47E100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, C16N47E100, NSX160N frame, 4P, 100 A, MicroLogic 7.2 E electronic trip unit, 90 kA Icu at 240 V AC.","salesMarkdown":"The C16N47E100 is a Schneider ComPacT NSX160N molded case circuit breaker with a MicroLogic 7.2 E electronic trip unit, rated 100 A at 40 °C. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage) protection — a full four-function package for distribution and feeder protection in a single device. The 90 kA Icu at 240 V AC (50/60 Hz) per IEC 60947-2 means it can safely interrupt a fault current up to that level without failing, which sets the SCCR for the downstream panel. At 480 V AC the interrupting rating is 50 kA Icu, still substantial for most industrial distribution boards. The N breaking capacity code (50 kA at 415 V AC) is the standard industrial grade in the ComPacT NSX family — above the S (25 kA) but below the H (70 kA) and L (150 kA) grades. The 90 kA at 240 V AC gives headroom for low-voltage transformer secondaries. The MicroLogic 7.2 E adds energy metering and communication (time-stamped histories, demand values, power quality data) — this is the trip unit that turns a breaker into a panel-level power monitor, not just a protection device. ## Mounting and integration — backplate, front connections, 35 mm pitch The toggle control with LCD display gives local status and settings visibility. ## Electrical and mechanical durability — cycles that define service life Mechanical durability is 40,000 cycles — the number of open-close operations the mechanism can perform without maintenance. Electrical durability varies with load: 40,000 cycles at 440 V at half rated current (In/2), 20,000 cycles at 440 V at full In, and 7,500 cycles at 690 V at full In. For a feeder breaker that operates infrequently (a few times per year for maintenance switching), this is effectively a lifetime rating. For a breaker used as a disconnect in a frequent-start application, the 20,000-cycle figure at rated current sets the replacement interval.","metaTitle":"C16N47E100 ComPacT NSX 160N, MicroLogic 7.2 E, 100 A, 90 kA","metaDescription":"Schneider C16N47E100 ComPacT NSX160N MCCB with MicroLogic 7.2 E trip unit, 100 A rated, 90 kA Icu at 240 V AC. EN/IEC 60947-2. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In","Mechanical Life Cycles":"40000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,683.91","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6771a993b8989180c9188d629482375d.pdf","sourceUrl":"https://www.se.com/za/en/product/C16N47E100/circuit-breaker-compact-nsx160n-50ka-415vac-4-poles-micrologic-vigi-7-2e-trip-unit-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C16N47E100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C16N47E100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C16N47E100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}