{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C2536M220","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C2536M220","canonicalUrl":"https://aoctrl.com/schneider/C2536M220","factsUrl":"https://aoctrl.com/api/mcp/products/C2536M220","rawCanonicalId":null},"summary":{"shortDescription":"Schneider C2536M220 Compact Nsx, New Generation — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The C2536M220 is a Schneider ComPacT NSX MicroLogic 6.2 E-M electronic trip unit rated 220 A at 65 °C for 3-pole fixed-mount circuit breakers. It is designed for motor protection and provides LSIG protection functions — long-time, short-time, instantaneous, and ground-fault — with zone selective interlocking (ZSI) for coordinated fault isolation. The trip unit includes an LCD display for energy metering, time-stamped event logs, and maintenance indicators. ## Protection & adjustment Long-time pickup Ir is adjustable from 100 to 220 A. Long-time delay Tr is adjustable with ranges depending on trip class: 120 s at 1.5 x Ir for class 5, up to 720 s at 1.5 x Ir for class 30. Short-time pickup Isd has 9 adjustable settings with fixed delay Tsd. Ground-fault pickup Ig is adjustable. The trip unit supports motor trip classes 5, 10, 20, and 30, and includes complementary motor protections such as underload, protracted starting, stalled rotor, and current unbalance. ## Compliance & environmental The C2536M220 complies with EN/IEC 60947-2 and is rated Class II (double insulation). The trip unit carries an 18-month warranty. ## Metering & display The integrated LCD display shows energy metering data, instantaneous and demand values, power quality metrics, and maximeters/minimeters. The unit records time-stamped histories and event tables, and provides maintenance indicators. Local signalling includes a flashing green LED for ready-to-operate and a red LED for temperature above 95 % Ith.","metaTitle":"Schneider C2536M220 MicroLogic 6.2 E-M trip unit, 220 A, 3-pole","metaDescription":"Schneider ComPacT NSX C2536M220 MicroLogic 6.2 E-M electronic trip unit, 220 A, 3-pole, LSIG, motor protection, EN/IEC 60947-2, Class II, LCD display.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Standards":"EN/IEC 60947-2","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX100...250","Trip unit rating":"220 A at 65 °C","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Motor","Type of measurement":"Energy meter","Motor tripping class":"30 5 10 20","Trip unit technology":"Electronic","Communication of data":"Energy metering Protection and alarm settings Time-stamped histories and event tables Instantaneous and demand values Maintenance indicators Demand current and power Power quality Maximeters/minimeters","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Electrical data recording":"Maintenance indicators","Product or component type":"Trip unit","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","Complementary motor protection":"Underload Protracted starting time Stalled rotor Current unbalance","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30 38 s at 6 x Ir for trip class 30 30 s at 7.2 x Ir for trip class 30","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable","[Ir] long-time protection pick-up adjustment range":"100...220 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for In = 50 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"3300 A","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$497.19 – $1,150.59","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0d6fcecdb04202cc9044b08ddf09ac9c.pdf","sourceUrl":"https://www.se.com/ie/en/product/C2536M220/trip-unit-micrologic-6-2em-compact-nsx250-3-poles-basic-and-ground-fault-protections-motor-energy-meter-220a/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C2536M220","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C2536M220 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}