{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25B34V160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25B34V160","canonicalUrl":"https://aoctrl.com/schneider/C25B34V160","factsUrl":"https://aoctrl.com/api/mcp/products/C25B34V160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, earth leakage circuit breaker, 3P, 160 A, MicroLogic 4.2 trip unit, 25 kA Icu at 415 V AC, IP40, backplate mount.","salesMarkdown":"It carries the MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection — the R protection function is built in, not an add-on module. Breaking capacity is 25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, sufficient for most distribution panelboard fault levels in commercial and light industrial installs. The B in the order code (C25B34V160) maps to that 25 kA class at 415 V. 160 A frame with a 160 A trip unit sized for 160 A continuous load. MicroLogic 4.2 provides L, So, I, and R protection curves in one electronic trip unit. Integrated earth-leakage saves a panel slot. For selectivity coordination downstream, the fixed-delay So curve lets you hold for a short interval so branch breakers clear first. Backplate mount, horizontal or vertical. Overvoltage category IV means it's suitable for main distribution boards, not just sub-panels. ## Integration notes Mounts on a backplate — no DIN rail adapter. 105 mm wide, 161 mm high, 86 mm deep. Front connections both upside and downside. The toggle handle is the control interface; the IΔn rotary switch sets the earth-leakage threshold. Five accessory slots available for auxiliary contacts, shunt trips, or motor operators. Electrical durability: 20,000 cycles at 440 V at half rated current, 10,000 cycles at full rated current. Mechanical durability: 20,000 cycles. That's typical for a distribution breaker — not a switching device for frequent motor starts.","metaTitle":"Schneider C25B34V160 ComPacT NSX Earth Leakage Breaker, 160","metaDescription":"Schneider C25B34V160 ComPacT NSX earth leakage circuit breaker, 160 A rated current, 25 kA breaking capacity at 415 V AC. MicroLogic 4.2 trip unit with integrated earth-leakage pro","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,164.41 – $2,511.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6c3d4a3491d978d1ddfb80a1b1f63d5.pdf","sourceUrl":"https://www.se.com/ph/en/product/C25B34V160/circuit-breaker-compact-nsx250b-25ka-415vac-3-poles-micrologic-vigi-4-2-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25B34V160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25B34V160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25B34V160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}