{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25F32D160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25F32D160","canonicalUrl":"https://aoctrl.com/schneider/C25F32D160","factsUrl":"https://aoctrl.com/api/mcp/products/C25F32D160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX250F, C25F32D160, 3P, 160 A at 40 °C, MicroLogic 2.2 electronic trip unit, 36 kA Icu at 415 V AC.","salesMarkdown":"## What this breaker brings to the panel The C25F32D160 is a ComPacT NSX250F 3-pole molded-case circuit breaker with a MicroLogic 2.2 electronic trip unit, rated 160 A at 40 °C. It's built for distribution duty (Category A) and carries a 36 kA Icu at 415 V AC (F breaking code), with 85 kA at 240 V and 22 kA at 525 V — so it handles high-fault commercial and light industrial mains without cascading upstream. The 105 mm width and 161 mm height fit standard ComPacT cutouts; depth is 86 mm. IP40 front face, IK07 impact rating — fine for enclosed panels where accidental tool drops are a risk.","metaTitle":"C25F32D160 ComPacT NSX250F Circuit Breaker, 160 A, MicroLogi","metaDescription":"C25F32D160 ComPacT NSX250F 3P circuit breaker, 160 A at 40 °C, MicroLogic 2.2 electronic trip unit, 36 kA at 415 V AC. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$441.82","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d4d6c46139f33d3ab7b01e7a0f71ed2e.pdf","sourceUrl":"https://www.se.com/nl/en/product/C25F32D160/circuit-breaker-compact-nsx250f-36ka-415vac-3-poles-micrologic-2-2-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25F32D160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25F32D160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25F32D160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}