{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25H32M220","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25H32M220","canonicalUrl":"https://aoctrl.com/schneider/C25H32M220","factsUrl":"https://aoctrl.com/api/mcp/products/C25H32M220","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX NSX250H, 3P, 220 A, MicroLogic 2.2 M electronic trip unit, 100 kA Icu at 240 V AC, motor protection application.","salesMarkdown":"The Schneider Electric C25H32M220 is a ComPacT NSX250H moulded-case circuit breaker (MCCB) with a 220 A MicroLogic 2.2 M electronic trip unit, configured for motor protection across three poles. The H breaking capacity code delivers 100 kA Icu at 240 V AC and 70 kA at 415 V AC, both certified to IEC 60947-2 — sufficient for high-fault industrial distribution where the upstream transformer can deliver that level of prospective short-circuit current. ## Trip unit and protection curves The MicroLogic 2.2 M provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous) protection, with motor tripping classes 5, 10, and 20 selectable. The 220 A rating at 65 °C means the breaker carries its full frame current without derating at that elevated ambient — critical for enclosed panels where internal temperature rise is a constraint. Rated 100 kA Icu at 240 V AC, 70 kA at 415 V AC, 65 kA at 440 V, 50 kA at 500 V, 35 kA at 525 V, and 10 kA at 690 V — all per IEC 60947-2. Under UL 60947-4-1 the ratings are 85 kA at 240 V, 65 kA at 480 V, and 15 kA at 600 V. ## Physical integration and environment Measures 161 x 105 x 86 mm (H x W x D), mounts on a backplate in horizontal or vertical orientation, and carries IP40 protection (IK07 impact resistance).","metaTitle":"Schneider Electric C25H32M220 ComPacT NSX250H, 220 A, 100 kA","metaDescription":"Schneider Electric C25H32M220 ComPacT NSX250H circuit breaker. 220 A MicroLogic 2.2 M trip unit, 100 kA Icu at 240 V AC, motor protection, IEC 60947-2. Available to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Motor protection","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$721.36","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/697803881b4dc746589474df8e983b19.pdf","sourceUrl":"https://www.se.com/nl/en/product/C25H32M220/circuit-breaker-compact-nsx250h-70ka-415vac-3-poles-micrologic-2-2m-trip-unit-220a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25H32M220/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25H32M220","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25H32M220 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}