{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25H44V160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25H44V160","canonicalUrl":"https://aoctrl.com/schneider/C25H44V160","factsUrl":"https://aoctrl.com/api/mcp/products/C25H44V160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider C25H44V160 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The C25H44V160 is a Schneider ComPacT NSX 4-pole molded case circuit breaker rated 160 A with a 100 kA breaking capacity at 440 V AC, fitted with a MicroLogic 4.2 electronic trip unit that provides overload, short-circuit, and earth-leakage protection. Compared to the 3-pole C25H3 (250 A, 85 kA at 690 V), the C25H44V160 adds a fourth pole for earth-leakage sensing and trades some ampacity for a higher 100 kA breaking capacity at 440 V. The C25H3 runs at 690 V insulation and 800 V AC withstand, so a panel wired for that voltage class cannot simply drop in the C25H44V160 without checking the system voltage and pole count.","metaTitle":"Schneider C25H44V160 ComPacT NSX 4-pole MCCB, 160 A, 100 kA","metaDescription":"Schneider C25H44V160 ComPacT NSX molded case circuit breaker: 4 poles, 160 A, 100 kA breaking capacity at 440 V AC, MicroLogic 4.2 trip unit, earth leakage protection.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"500 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Earth leakage circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,407.81 – $3,389.58","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/99caf06c7280e2b1ce4f4061fdb23007.pdf","sourceUrl":"https://www.se.com/vn/en/product/C25H44V160/circuit-breaker-compact-nsx250h-70ka-415vac-4-poles-micrologic-vigi-4-2-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25H44V160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25H44V160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25H44V160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}