{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25V3TM160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25V3TM160","canonicalUrl":"https://aoctrl.com/schneider/C25V3TM160","factsUrl":"https://aoctrl.com/api/mcp/products/C25V3TM160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip unit, 85 kA Icu at 500 V AC, IEC 60947-2.","salesMarkdown":"The C25V3TM160 is a Schneider Electric ComPacT NSX circuit breaker with a 160 A TM-D thermal-magnetic trip unit, rated 85 kA Icu at 500 V AC per IEC 60947-2. The TM-D trip gives you fixed thermal overload (L) and fixed magnetic short-circuit (I) protection; no interchangeable rating plugs, so what you order is what protects the circuit. The 105 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX panel cutouts; if you're retrofitting an older NS or NSJ breaker, check the door cutout and busbar centers because the mounting footprint changed between generations. If your panel runs hotter, expect a reduction; the trip unit is thermal-magnetic so the thermal element responds to both current and ambient temperature. Power dissipation is 11.78 W per pole, so three poles at 160 A shed about 35 W total — plan ventilation if the enclosure is sealed and densely packed.","metaTitle":"C25V3TM160 ComPacT NSX 160 A, 85 kA Icu, Thermal-Magnetic","metaDescription":"C25V3TM160 ComPacT NSX circuit breaker, 160 A TM-D trip unit, 85 kA Icu at 500 V AC, EN/IEC 60947-2. Current lifecycle stage. Sourced to order — RFQ for availability and pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$986.71","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b2f00ebf55e503c60c4d0f2e6559c65f.pdf","sourceUrl":"https://www.se.com/vn/en/product/C25V3TM160/circuit-breaker-compact-nsx250hb1-75ka-690vac-3-poles-tmd-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25V3TM160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25V3TM160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25V3TM160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}