{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25V46E100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25V46E100","canonicalUrl":"https://aoctrl.com/schneider/C25V46E100","factsUrl":"https://aoctrl.com/api/mcp/products/C25V46E100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX250HB1 frame, 4P, 100 A at 40 °C, MicroLogic 6.2 E electronic trip unit, 85 kA Icu at 500 V AC, EN/IEC 60947-2.","salesMarkdown":"## What this MCCB brings to a distribution panel The C25V46E100 is a Schneider Electric ComPacT NSX moulded-case circuit breaker in the NSX250HB1 frame, rated 100 A at 40 °C with a 4-pole configuration. It carries the MicroLogic 6.2 E electronic trip unit, which provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection in a single device — covering the full protection curve without needing separate relays or add-on modules. The breaking capacity is 85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, stepping down to 80 kA at 525 V and 75 kA at 690 V. That puts it in the HB1 class — high-interrupting for industrial distribution where fault currents can exceed 50 kA. The 4-pole design with neutral on the left suits three-phase plus neutral distribution in panelboards feeding mixed single-phase and three-phase loads. ## What the MicroLogic 6.2 E trip unit means for selectivity It logs time-stamped histories, event tables, demand current and power, power quality data, and protection/alarm settings — data that a facility engineer can pull for predictive maintenance or post-fault analysis without adding a separate power monitor. If the load re-energises while the conductor is still hot, the trip curve shifts to prevent re-closing into a still-overloaded condition — a detail that matters for motor circuits or high-inertia loads that draw inrush after a brief interruption. ## Mounting and integration into a switchboard The 35 mm connection pitch matches standard busbar systems, and the 161 mm height by 140 mm width by 86 mm depth fits within a typical distribution section without crowding adjacent breakers. The IK07 impact rating confirms it withstands a 2 J impact, enough for accidental tool drops during maintenance.","metaTitle":"Schneider Electric C25V46E100 ComPacT NSX 100A 4P MCCB, Micr","metaDescription":"Schneider Electric C25V46E100 ComPacT NSX 250A frame MCCB, 100 A rated, 4-pole, MicroLogic 6.2 E trip unit with LSI+G protection. 85 kA Icu at 500 V AC. Active production, sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,427.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a6fd11c9153132e63883b5aa16222db.pdf","sourceUrl":"https://www.se.com/be/en/product/C25V46E100/circuit-breaker-compact-nsx250hb1-75ka-690vac-4-poles-micrologic-6-2e-trip-unit-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25V46E100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25V46E100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25V46E100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}