{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25V46E160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25V46E160","canonicalUrl":"https://aoctrl.com/schneider/C25V46E160","factsUrl":"https://aoctrl.com/api/mcp/products/C25V46E160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, 160 A, 4P, MicroLogic 6.2 E electronic trip unit, 85 kA Icu at 500 V AC, EN/IEC 60947-2.","salesMarkdown":"The C25V46E160 is a Schneider Electric ComPacT NSX moulded-case circuit breaker, 4-pole, with a 160 A frame and a MicroLogic 6.2 E electronic trip unit. It is designed for distribution applications and complies with EN/IEC 60947-2. The MicroLogic 6.2 E provides LSI protection — long-time overload (L), short-time short-circuit (S), and instantaneous short-circuit (I) — plus ground-fault protection (G). That means a single device covers overload, short-circuit, and ground-fault coordination, which simplifies panel design and reduces the number of components. ## Breaking capacity and what it means for your system The breaking capacity is 85 kA Icu at 500 V AC 50/60 Hz, 80 kA at 525 V, and 75 kA at 660/690 V. For a 500 V distribution board with a prospective fault current of, say, 65 kA, this breaker clears it safely. The 75 kA at 690 V is relevant for 690 V industrial networks common in mining or heavy manufacturing. Utilisation category A means it is not intended for motor starting duty — it is a distribution breaker, not a motor circuit protector. ## Trip unit and metering capability The MicroLogic 6.2 E is an electronic trip unit with an LCD display and local signalling — a flashing green LED for ready, red LED at 105 % Ir for overload, orange at 90 % Ir. It includes an energy meter and communicates energy metering, power quality, demand current, time-stamped events, and protection settings. Mounts on a backplate in horizontal or vertical orientation, flat on the back. The 4-pole version with neutral on the left has a width of 140 mm, height 161 mm, depth 86 mm. Connection pitch is 35 mm. Front connections both upside and downside. ## Durability and environmental ratings Electrical durability varies with load: 20,000 cycles at 440 V at half rated current, 10,000 at full rated current at 440 V, 10,000 at 690 V at half current, and 5,000 at 690 V full current. That is typical for a distribution MCCB — not designed for frequent switching like a contactor, but adequate for infrequent isolation and fault interruption. IK07 impact resistance means it withstands a 2 J impact, enough for accidental tool drops in a panel. Relative humidity 0–95 %.","metaTitle":"C25V46E160 ComPacT NSX 160A 4P MCCB, MicroLogic 6.2 E, 85kA","metaDescription":"C25V46E160 ComPacT NSX 160A 4P MCCB with MicroLogic 6.2 E trip unit. 85 kA Icu at 500 V AC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$13.63","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51cb4f3fa9665fac825bbd9b5b91dd5e.pdf","sourceUrl":"https://www.se.com/th/en/product/C25V46E160/circuit-breaker-compact-nsx250hb1-75ka-690vac-4-poles-micrologic-6-2e-trip-unit-160a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25V46E160/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25V46E160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25V46E160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}