{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25V46E250","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25V46E250","canonicalUrl":"https://aoctrl.com/schneider/C25V46E250","factsUrl":"https://aoctrl.com/api/mcp/products/C25V46E250","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX250HB1, C25V46E250, 250 A rated, 85 kA Icu at 500 V AC, 4-pole, MicroLogic 6.2 E electronic trip unit.","salesMarkdown":"It is a 4-pole, 250 A rated breaker designed for distribution applications, using an electronic MicroLogic 6.2 E trip unit that provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection. The breaker is rated at 85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, and carries a 75 kA Icu at 690 V AC — the HB1 breaking capacity code tells you it handles high fault currents at higher voltages. This is not a residential-grade breaker; it belongs in an industrial panel where selectivity and coordination matter. The MicroLogic 6.2 E trip unit is fully electronic, so you can adjust the long-time pickup, short-time delay, and instantaneous settings to coordinate with downstream breakers — not a fixed thermal-magnetic curve. The 4-pole version (4P) with neutral on the left means it switches all four poles, including the neutral, which is required for some IT or corner-grounded delta systems. The connection pitch is 35 mm, and both upside and downside connections are front-facing, which simplifies bus-bar or cable routing in a panel. The breaker is 161 mm high, 140 mm wide, and 86 mm deep, with an IK07 impact rating per IEC 62262 — tough enough for a panel environment but not for direct mechanical abuse. ## Communication and metering The MicroLogic 6.2 E trip unit includes an energy meter and communicates time-stamped histories, event tables, protection and alarm settings, maximeters/minimeters, instantaneous and demand values, power quality data, energy metering, demand current and power, and maintenance indicators. The LCD display on the front gives local readout without needing a separate meter or gateway — useful for a commissioning engineer checking load profiles or for an MRO planner verifying trip history after a fault.","metaTitle":"Schneider Electric C25V46E250 ComPacT NSX 250A, 85kA 500V AC","metaDescription":"Schneider Electric C25V46E250 ComPacT NSX250HB1 molded case circuit breaker, 250A rated, 85kA Icu at 500V AC, MicroLogic 6.2 E trip unit, LSI+G protection. Active production, sourc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Display type":"LCD display","Network type":"AC","Product name":"ComPacT NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"250 A at 40 °C","Breaking capacity":"85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX250HB1","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"250 A at 40 °C","Downside connection":"Front","Type of measurement":"Energy meter","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Time-stamped histories and event tables Protection and alarm settings Maximeters/minimeters Instantaneous and demand values Power quality Energy metering Demand current and power Maintenance indicators","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"HB1 75 kA 690 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"0.5 x Ir (3D + N/2) 1 x Ir (4D) 1.6 x Ir (3D + OSN) No protection (3D)","Power dissipation per pole":"17.6 W","Protected poles description":"4D 3D + OSN 3D + N/2 3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"15...400 s at 1.5 x Ir 0.5...16 s at 6 x Ir 0.35...11 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","[Tsd] Short-Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","[Ig] ground-fault pick-up adjustment range":"0.4...1 x In for In = 40 A 0.2...1 x In for In > 40 A Ig enable on/off","Long-time protection delay adjustment type tr":"Adjustable","[tg] Ground-fault time delay adjustment range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Short-time protection delay adjustment type tsd":"Adjustable 5 settings","Short-time protection pick-up adjustment type Isd":"Adjustable","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"100...250 A","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable 5 settings","[Ii] instantaneous protection pick-up adjustment range":"1.5...12 x In","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$13.63","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dd5286c3989482c2073b85b7045d34f6.pdf","sourceUrl":"https://www.se.com/ie/en/product/C25V46E250/circuit-breaker-compact-nsx250hb1-75ka-690vac-4-poles-micrologic-6-2e-trip-unit-250a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25V46E250/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25V46E250","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25V46E250 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}