{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C25W36M220","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C25W36M220","canonicalUrl":"https://aoctrl.com/schneider/C25W36M220","factsUrl":"https://aoctrl.com/api/mcp/products/C25W36M220","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX250HB2, MCCB, 3P, 220 A at 65 °C, 100 kA Icu at 690 V AC, MicroLogic 6.2 E-M electronic trip unit, motor protection.","salesMarkdown":"The Schneider Electric C25W36M220 is a ComPacT NSX250HB2 moulded-case circuit breaker (MCCB) with a MicroLogic 6.2 E-M electronic trip unit, rated 220 A at 65 °C. It is built for motor protection in industrial distribution panels, carrying a 100 kA Icu breaking capacity at 690 V AC 50/60 Hz per IEC 60947-2. The 3-pole unit uses a toggle control and an LCD display for local metering and protection settings. Motor tripping classes 5, 10, 20, and 30 are selectable, letting you match the trip curve to the motor's starting profile — class 10 for standard induction motors, class 20 or 30 for high-inertia loads like crushers or centrifuges. The 105 mm width and 161 mm height fit standard MCCB panel cutouts. ## Deployment context This MCCB is sized for motor feeder circuits in industrial control panels — typically feeding a motor starter or soft starter for pumps, conveyors, compressors, or fans. The electronic trip unit with ground-fault protection suits applications where earth-leakage detection is required without a separate relay. The LCD display provides real-time energy metering, demand current, and time-stamped event logs, useful for predictive maintenance without an external power meter. Design complies with EN/IEC 60947-2 for low-voltage switchgear and controlgear. The enclosure carries IK07 impact protection per IEC 62262. Mechanical durability is rated at 20,000 cycles; electrical durability ranges from 5,000 cycles at 690 V In to 20,000 cycles at 440 V In/2.","metaTitle":"Schneider C25W36M220 ComPacT NSX 220A MCCB, 100kA 690V","metaDescription":"Schneider Electric C25W36M220 ComPacT NSX250HB2 MCCB with MicroLogic 6.2 E-M trip unit. 220A rated, 100 kA Icu at 690 V AC. Motor protection, electronic trip, LCD display. Active p","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","Control type":"Toggle","Display type":"LCD display","Network type":"AC","Product name":"ComPacT NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"220 A at 65 °C","Breaking capacity":"100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX250HB2","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Motor protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"220 A at 65 °C","Downside connection":"Front","Type of measurement":"Energy meter","Motor tripping class":"30 5 10 20","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Time-stamped histories and event tables Power quality Demand current and power Maximeters/minimeters Protection and alarm settings Maintenance indicators Instantaneous and demand values Energy metering Phase sequence Thermal image function","Electrical durability":"20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"HB2 100 kA 690 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"17.6 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Complementary motor protection":"Stalled rotor Phase unbalance Underload Protracted starting time","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30 38 s at 6 x Ir for trip class 30 30 s at 7.2 x Ir for trip class 30","[Uimp] rated impulse withstand voltage":"8 kV","[Ig] ground-fault pick-up adjustment range":"0.6...1 x In for In = 25 A 0.3...1 x In for In = 50 A 0.2...1 x In for In > 50 A Ig enable on/off","Long-time protection delay adjustment type tr":"Adjustable","[tg] Ground-fault time delay adjustment range":"0...0.4 s","Short-time protection delay adjustment type tsd":"Fixed","Short-time protection pick-up adjustment type Isd":"Adjustable","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"100...220 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable 5 settings","[Ii] instantaneous protection pick-up adjustment range":"3300 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,034.02","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/34c174f431d8d9a1422fdc7f2ec0fa30.pdf","sourceUrl":"https://www.se.com/za/en/product/C25W36M220/circuit-breaker-compact-nsx250hb2-100ka-at-690vac-micrologic-6-2-em-trip-unit-220a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C25W36M220/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C25W36M220?","answer":"It has a 100 kA Icu breaking capacity at 500 V, 525 V, and 660/690 V AC 50/60 Hz per IEC 60947-2."},{"question":"What protection functions does the MicroLogic 6.2 E-M trip unit provide?","answer":"It provides L (long-time overload), So (short-time short-circuit), I (instantaneous), and G (ground-fault) protection, with selectable motor tripping classes 5, 10, 20, and 30."},{"question":"Where can I buy C25W36M220 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What compliance documentation does Schneider provide for C25W36M220?","answer":"The breaker complies with EN/IEC 60947-2 and carries IK07 impact protection per IEC 62262. Schneider provides a declaration of conformity and test certificates; consult the product documentation for RoHS and REACH status."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C25W36M220","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C25W36M220 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}