{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C40H32D250","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C40H32D250","canonicalUrl":"https://aoctrl.com/schneider/C40H32D250","factsUrl":"https://aoctrl.com/api/mcp/products/C40H32D250","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX400H frame, 3-pole circuit breaker, 250 A MicroLogic 2.3 electronic trip unit, 70 kA Icu at 415 V AC, toggle control.","salesMarkdown":"The C40H32D250 is a Schneider Electric ComPacT NSX circuit breaker in the NSX400H frame, 3-pole, with a MicroLogic 2.3 electronic trip unit rated 250 A at 40 °C. It's a distribution breaker, not a motor-circuit protector — the trip unit gives you LSI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I). That makes it a good fit for main or feeder breakers in a panel where you need selective coordination downstream. That's the kind of detail that matters when you're protecting a transformer or a long cable run that takes time to cool. But the full curve matters more. At 240 V AC you get 100 kA Icu; at 480 V AC (UL rating) it's 65 kA; at 600 V AC it drops to 20 kA. If your system fault current is, say, 85 kA at 240 V, this breaker handles it. But at 480 V you need to stay under 65 kA. That's the kind of thing a site electrical engineer checks against the utility's fault study before committing the BOM line. ## Mounting and environment — panel integration notes Mounts on a backplate, front-connected both top and bottom. Connection pitch is 45 mm. It can be mounted horizontal, vertical, or flat on the back, which gives flexibility in tight enclosures. ## Durability — how many operations before replacement Mechanical durability is 15,000 cycles. Electrical durability depends on the load: 12,000 cycles at 440 V at half rated current (In/2), 6,000 cycles at 440 V at full In, and 3,000 cycles at 690 V at full In. If this breaker is in a frequent-switching application like a capacitor bank or a welding line, those numbers tell you when to plan a replacement.","metaTitle":"C40H32D250 ComPacT NSX 250A 3P Circuit Breaker, 70kA 415V","metaDescription":"C40H32D250 ComPacT NSX 400H frame circuit breaker. 250A MicroLogic 2.3 electronic trip unit, 70kA Icu at 415V AC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"140 mm","Height":"255 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In","Mechanical Life Cycles":"15000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$833.26","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/413d5b9994d4047de8996afabe024771.pdf","sourceUrl":"https://www.se.com/nl/en/product/C40H32D250/circuit-breaker-compact-nsx400h-70ka-415vac-3-poles-micrologic-2-3-trip-unit-250a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C40H32D250/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C40H32D250","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C40H32D250 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}