{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C40W46E400","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C40W46E400","canonicalUrl":"https://aoctrl.com/schneider/C40W46E400","factsUrl":"https://aoctrl.com/api/mcp/products/C40W46E400","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX400HB2, 400 A, 100 kA Icu at 690 V AC, 4P, MicroLogic 6.3 E electronic trip unit, LCD display, toggle control.","salesMarkdown":"The C40W46E400 is a ComPacT NSX molded case circuit breaker (MCCB) rated 400 A at 40 °C, with a MicroLogic 6.3 E electronic trip unit providing L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground fault) protection. The 4-pole (4P) configuration with neutral on the left suits three-phase plus neutral distribution panels, and the 185 mm width and 255 mm height fit standard backplate mounting patterns. ## Trip unit and metering capability The LCD display and energy meter function give real-time demand current, power quality, and time-stamped event logs, which a panel builder can use for load profiling without adding a separate power monitor. The IK07 impact rating (IEC 62262) handles accidental tool drops during commissioning.","metaTitle":"C40W46E400 ComPacT NSX 400A, 100kA Icu 690V AC, MicroLogic 6","metaDescription":"Schneider Electric C40W46E400 ComPacT NSX400HB2 molded case circuit breaker, 400 A, 100 kA Icu at 690 V AC, MicroLogic 6.3 E electronic trip unit, 4P, LCD display. Active productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"185 mm","Height":"255 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Display Type":"LCD display","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In","Mechanical Life Cycles":"15000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$23.57","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/26b7beaa42a304002babb9f53addfb3d.pdf","sourceUrl":"https://www.se.com/au/en/product/C40W46E400/circuit-breaker-compact-nsx400hb2-100ka-690vac-4-poles-micrologic-6-3e-trip-unit-400a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C40W46E400/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C40W46E400","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C40W46E400 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}