{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P16AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P16AB","canonicalUrl":"https://aoctrl.com/schneider/C60H1P16AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P16AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Multi9 series, C60H miniature circuit breaker, C60H1P16AB, 16 A, B-curve, 1-pole, 15 kA breaking capacity at 230-240 V AC.","salesMarkdown":"The C60H1P16AB is a 1-pole miniature circuit breaker from the Schneider Electric Multi9 range, rated 16 A at 30 °C with a B-curve (magnetic trip 3–5 × In). The 73 mm depth leaves room for gland plates and cable bends in a compact enclosure. Rated breaking capacity (Icu) hits 15 kA at 230–240 V AC, 20 kA at 60 V DC, and 4 kA at 400–415 V AC per IEC 60947-2. For selectivity studies, the B-curve's 3–5× In magnetic threshold gives a wider gap upstream of C-curve or D-curve devices. Fixed mounting on 35 mm DIN rail. The toggle provides local ON/OFF indication and a contact position indicator confirms isolation status — suitable for lockout/tagout verification per IEC 60947-2.","metaTitle":"C60H1P16AB MCB, 16 A, Curve B, 1P, 15 kA","metaDescription":"Schneider Electric C60H1P16AB miniature circuit breaker, 16 A rated current, B-curve, 1-pole, 15 kA breaking capacity at 230-240 V AC. Active production, sourced to order. Request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"3...5 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 2 kA conforming to IEC 60947-2 AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P16AB/miniature-circuit-breaker-c60h-1-pole-16-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P16AB/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H1P16AB and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to C60H1P16AB?","answer":"Within the same Multi9 C60 family, the C60H1P16AB is the standard 16 A B-curve 1-pole variant. A C60N or C60L version would differ in breaking capacity (lower or higher Icu), not in footprint or wiring — check the required SCCR before substituting."},{"question":"What compliance documentation does this brand provide for C60H1P16AB?","answer":"The breaker is designed to IEC 60947-2 (limitation class 3, isolation suitability) and IEC 60068-1 (tropicalisation class 2). Typical documentation includes a declaration of conformity, IEC test reports, and a CE declaration — request these with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P16AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P16AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}