{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P20AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P20AD","canonicalUrl":"https://aoctrl.com/schneider/C60H1P20AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P20AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H C60H1P20AD, miniature circuit breaker, D curve, 20 A, 1 pole, 15 kA breaking capacity at 230 V AC, thermal-magnetic trip unit.","salesMarkdown":"The C60H1P20AD is a 1-pole miniature circuit breaker from the Multi9 C60H series, rated 20 A at 40 °C with a D tripping curve. The 15 kA breaking capacity at 230–240 V AC (Icu per IEC 60947-2) tells you it can safely interrupt a fault up to that level without welding the contacts or cascading upstream. The 18 mm width (2 × 9 mm pitches) means it occupies a single modular slot in a standard distribution board — no special adapter needed. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible conductors; tighten to 2 N·m. The toggle actuator gives local ON/OFF indication and a contact position indicator confirms isolation status per IEC 60947-2.","metaTitle":"Schneider Electric C60H1P20AD MCB, D Curve, 20 A, 1P, Multi9","metaDescription":"Schneider Electric C60H1P20AD miniature circuit breaker, D curve, 20 A rated current, 1 pole, 15 kA breaking capacity at 230 V AC, Multi9 range. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"20 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 2 kA conforming to IEC 60947-2 AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P20AD/miniature-circuit-breaker-c60h-1-pole-20-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P20AD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H1P20AD and what is the lead time?","answer":"The C60H1P20AD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to C60H1P20AD in the Multi9 family?","answer":"Within the same C60H series, the main alternative is a different curve or rating — for example, a C60H with a C curve (magnetic trip 5–10 × In) for general-purpose distribution, or a higher/lower amp rating. The D curve here is specific to high-inrush loads; swapping to a C curve risks nuisance trips on motor or transformer startup. There is no pin-compatible alternate with identical electrical ratings and curve."},{"question":"What compliance documentation does Schneider provide for C60H1P20AD?","answer":"The breaker carries IEC 60947-2 certification (breaking capacity, isolation suitability, limitation class 3). It also conforms to IEC 60068-1 for tropicalisation (damp heat). RoHS and REACH declarations are standard for the Multi9 range; specific certificates are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P20AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P20AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}