{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P32AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P32AD","canonicalUrl":"https://aoctrl.com/schneider/C60H1P32AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P32AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, C60H1P32AD, miniature circuit breaker, 1P, 32 A, D curve, 15 kA breaking capacity at 230-240 V AC.","salesMarkdown":"The Schneider Electric C60H1P32AD is a 1-pole miniature circuit breaker from the Multi9 C60 range, rated 32 A at 40 °C with a D tripping curve. It is a thermal-magnetic MCB, meaning the bimetal handles overloads and the solenoid handles short-circuits, all in a single 18 mm wide DIN-rail module. Rated breaking capacity hits 15 kA Icu at 230–240 V AC (IEC 60947-2), with a corresponding Ics of 15 kA at 12–440 V AC — meaning it can clear a fault and be reclosed at full rating. The 6 kV impulse withstand (Uimp) and 500 V insulation voltage (Ui) keep it coordinated with standard distribution gear. Tunnel terminals accept up to 25 mm² flexible or 35 mm² rigid cable; strip length is 14 mm, tighten to 3.5 N·m. Rated for operation from -25 °C to 60 °C, storage from -40 °C to 70 °C, and 95 % relative humidity at 55 °C. Tropicalisation per IEC 60068-1 (2 levels) and limitation class 3 per IEC 60947-2.","metaTitle":"Schneider Electric C60H1P32AD MCB, 32 A, D Curve, 1P, Multi9","metaDescription":"Schneider Electric C60H1P32AD miniature circuit breaker, 32 A rated current, D curve, 1 pole, 15 kA breaking capacity at 230-240 V AC. Multi9 range. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"10...14 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 2 kA conforming to IEC 60947-2 AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P32AD/miniature-circuit-breaker-c60h-1-pole-32-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P32AD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H1P32AD and get a price?","answer":"The C60H1P32AD is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the D curve on this MCB for?","answer":"The D curve (magnetic trip at 10–14 × In) is intended for loads with high inrush currents such as motor starters, small transformers, and discharge lighting, where a B or C curve would trip on startup."},{"question":"What is the breaking capacity of C60H1P32AD?","answer":"The breaking capacity is 15 kA Icu at 230–240 V AC and 4 kA Icu at 400–415 V AC, both per IEC 60947-2. The service breaking capacity Ics is 15 kA at 12–440 V AC."},{"question":"What compliance documentation does this brand provide for C60H1P32AD?","answer":"The C60H1P32AD is certified for isolation per IEC 60947-2, with tropicalisation per IEC 60068-1 and limitation class 3 per IEC 60947-2. Standard documentation includes the manufacturer's declaration of conformity; specific RoHS/REACH/UL status should be confirmed at time of order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P32AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P32AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}