{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P40AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P40AB","canonicalUrl":"https://aoctrl.com/schneider/C60H1P40AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P40AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H1P40AB, Multi9 C60H range, miniature circuit breaker, 1-pole, 40 A, B-curve, 15 kA breaking capacity at 230 V AC, DIN rail mount.","salesMarkdown":"The C60H1P40AB is a 1-pole 40 A miniature circuit breaker from Schneider's Multi9 C60H range, B-curve characteristic. It occupies 2 x 9 mm module pitches (18 mm width) on a 35 mm symmetrical DIN rail, fixed mounting. Breaking capacity is 15 kA Icu at 230...240 V AC (IEC 60947-2), with a corresponding Ics service breaking capacity of 15 kA at 12...440 V AC. At 400...415 V AC the Icu drops to 4 kA, so for three-phase panel feeders this unit is best applied on single-phase branch circuits or as a backup device coordinated with an upstream higher-rated breaker. Rated operational voltage is 440 V AC, insulation voltage 500 V AC, impulse withstand 6 kV. Tunnel-type terminals accept up to 35 mm² rigid or 25 mm² flexible conductors, strip length 14 mm, tighten to 3.5 N·m. Ambient operating range is -25 to 60 °C, storage -40 to 70 °C, with 95 % RH at 55 °C. Tropicalisation level 2 per IEC 60068-1 means the unit is treated for high-humidity environments — suitable for coastal or unconditioned plant rooms.","metaTitle":"C60H1P40AB MCB, 40A B-Curve 1P, Multi9, 15kA Breaking","metaDescription":"Schneider C60H1P40AB miniature circuit breaker, 40A B-curve, 1-pole, 15kA breaking capacity at 230V AC. Multi9 range, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"40 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"3...5 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 2 kA conforming to IEC 60947-2 AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P40AB/miniature-circuit-breaker-c60h-1-pole-40-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P40AB/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H1P40AB?","answer":"15 kA Icu at 230...240 V AC, 20 kA Icu at 60 V DC (1-pole), and 30 kA Icu at 130 V AC, all per IEC 60947-2. At 400...415 V AC the Icu is 4 kA. The Ics service breaking capacity is 15 kA at 12...440 V AC."},{"question":"What does the B-curve mean on this breaker?","answer":"The B-curve (magnetic trip 3 to 5 x In) means the breaker trips instantaneously between 120 A and 200 A. It is designed for resistive loads and light inductive loads where inrush is low, such as lighting circuits, socket outlets, and general-purpose distribution."},{"question":"Where can I buy C60H1P40AB?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P40AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P40AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}