{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P4AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P4AD","canonicalUrl":"https://aoctrl.com/schneider/C60H1P4AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P4AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60, C60H1P4AD, miniature circuit breaker, 1-pole, 4 A rated current, D curve, 15 kA breaking capacity at 230 V AC, DIN-rail mount.","salesMarkdown":"The Schneider Electric C60H1P4AD is a 1-pole miniature circuit breaker from the Multi9 C60 series, rated 4 A at 40 °C with a D tripping curve. The D curve means its magnetic trip operates between 10 and 14 times the rated current (40 to 56 A instantaneous trip), making it the right choice for loads with high inrush — think motor starters, small transformers, or discharge lighting where a B or C curve would nuisance-trip on startup. The thermal-magnetic trip unit handles the overload side. Breaking capacity is 15 kA Icu at 230...240 V AC (IEC 60947-2), which covers most commercial and light industrial distribution panels. At 400...415 V AC the rating drops to 4 kA — still adequate for sub-distribution in a 400 V system where the upstream device limits fault current. The 18 mm width (2 x 9 mm pitches) means it occupies a single module slot in a standard distribution board — no surprises for panel fill calculations. Depth is 73 mm, height 81 mm. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible cable; strip length is 14 mm, tighten to 2 N·m. Rated operational voltage (Ue): 440 V AC. Rated insulation voltage (Ui): 500 V AC. Impulse withstand (Uimp): 6 kV. Tropicalisation class 2 per IEC 60068-1, limitation class 3 per IEC 60947-2. Operating temperature range -25 to 60 °C, storage -40 to 70 °C. Mechanical durability: 20,000 cycles.","metaTitle":"Schneider Electric C60H1P4AD C60 MCB, 1P, 4A, D Curve","metaDescription":"Schneider Electric C60H1P4AD miniature circuit breaker, 1-pole, 4 A rated current, D tripping curve, 15 kA breaking capacity at 230 V AC. DIN-rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"4 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 2 kA conforming to IEC 60947-2 AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P4AD/miniature-circuit-breaker-c60h-1-pole-4-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P4AD/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for C60H1P4AD?","answer":"The C60H1P4AD is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote to confirm current pricing and availability."},{"question":"What is the D curve on this MCB for?","answer":"The D curve trips magnetically at 10 to 14 times the rated current, so it handles high inrush loads like motor starters, small transformers, and discharge lighting without nuisance tripping on startup."},{"question":"What compliance documentation does this brand provide for C60H1P4AD?","answer":"The C60H1P4AD is designed and tested to IEC 60947-2, with tropicalisation per IEC 60068-1. Standard Schneider documentation includes the datasheet, IEC declaration of conformity, and environmental compliance data (RoHS, REACH)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P4AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P4AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}