{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H1P63AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H1P63AB","canonicalUrl":"https://aoctrl.com/schneider/C60H1P63AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H1P63AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H1P63AB, Multi9 C60H series, 1-pole miniature circuit breaker, 63 A rated current, B-curve, 10 kA Icn per EN 60898, 15 kA Icu at 230 V AC per IEC 60947-2.","salesMarkdown":"The Schneider Electric C60H1P63AB is a 1-pole miniature circuit breaker from the Multi9 C60H series, rated 63 A at 30 °C with a B-curve (magnetic trip between 3 and 5 times In). The B-curve means the magnetic trip activates at 3 to 5 times the rated current — 189 A to 315 A for this 63 A unit — making it suited for resistive or general-purpose loads where inrush is moderate, not for motor-starting or transformer primaries that would need a C or D curve. This breaker carries dual ratings: 10 kA Icn at 230/400 V AC per EN 60898 (the standard for household-type MCBs), and 15 kA Icu at 230...240 V AC per IEC 60947-2 (the industrial standard). The IEC 60947-2 rating also gives 20 kA Icu at 60 V DC (1P) and 4 kA Icu at 400...415 V AC. For a 63 A feed in a typical 230 V single-phase distribution board, the 10 kA Icn covers most utility fault levels. ## Integration notes — DIN rail and wiring Snaps onto 35 mm symmetrical DIN rail.","metaTitle":"Schneider C60H1P63AB MCB, 63A Curve B, 1P, Multi9","metaDescription":"Schneider Electric C60H1P63AB miniature circuit breaker, 63 A rated current, curve B, 1 pole, 10 kA Icn per EN 60898, 15 kA Icu at 230 V per IEC 60947-2. Multi9 range. Sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"18 mm","Height":"81 mm","Standards":"EN 60898 IEC 60947-2","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"15 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 60 V DC 1P conforming to IEC 60947-2 30 kA Icu at 130 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"63 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"3...5 x In","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"2 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz 25 kA conforming to IEC 60947-2 - 130 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H1P63AB/miniature-circuit-breaker-c60h-1-pole-63-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H1P63AB/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H1P63AB?","answer":"It has 10 kA Icn at 230/400 V AC per EN 60898 and 15 kA Icu at 230...240 V AC per IEC 60947-2. At 400...415 V AC the Icu is 4 kA, and at 60 V DC it is 20 kA (1 pole)."},{"question":"Where can I buy the C60H1P63AB?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote."},{"question":"What compliance documentation does Schneider provide for C60H1P63AB?","answer":"The breaker is certified to EN 60898 and IEC 60947-2. It carries a CE marking for the European market and is suitable for isolation per IEC 60947-2. Specific RoHS/REACH declarations are available from Schneider Electric upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H1P63AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H1P63AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}