{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P10AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P10AB","canonicalUrl":"https://aoctrl.com/schneider/C60H2P10AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P10AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, miniature circuit-breaker C60H2P10AB, 1P+N, 10 A rated, curve B, 10 kA breaking capacity at 440 V AC, DIN rail mount.","salesMarkdown":"The C60H2P10AB is a 1P+N miniature circuit-breaker from the Multi9 C60 range, rated 10 A at 30 °C with a B-curve trip characteristic (magnetic trip between 3 and 5 times In). That B-curve means it trips fast on moderate overloads — good for resistive or general-purpose loads where you want to protect wiring, not for motor starting where the inrush would nuisance-trip it. That's another SKU I don't need to second-guess on the shelf. ## Deployment context This breaker lives in a distribution board — typically a sub-distribution panel feeding lighting, socket outlets, or small resistive loads. The 1P+N configuration switches the phase and protects it, with the neutral on the left (fixed position) and unswitched. The toggle gives local ON/OFF indication; the contact position indicator confirms isolation visually. Altitude rating is 2000 m standard; above that you'd need to derate.","metaTitle":"C60H2P10AB Miniature Circuit-Breaker, 10 A, Curve B, 1P+N, M","metaDescription":"C60H2P10AB MCB, 10 A rated, curve B, 1P+N, 10 kA breaking capacity at 440 V AC. DIN rail mount, thermal-magnetic trip, current lifecycle. Available to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P10AB/miniature-circuit-breaker-c60h-2-poles-10-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P10AB/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for C60H2P10AB?","answer":"Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront; we source through independent distribution channels and can quote current market pricing and lead time."},{"question":"What is the closest alternative to C60H2P10AB in the same family?","answer":"Within the Multi9 C60 range, the closest sibling is the C60H2P10AC (same 10 A, 1P+N, same breaking capacity, but with a C-curve for moderate inrush loads like small motors or transformers). The physical footprint, terminal capacity, and DIN rail mounting are identical — the only difference is the magnetic trip threshold (5-10 x In for C-curve vs 3-5 x In for B-curve). Choose B for resistive/lighting circuits; choose C for mixed loads with some motor or transformer inrush."},{"question":"What compliance documentation does Schneider provide for C60H2P10AB?","answer":"The C60H2P10AB is designed and tested to IEC 60947-2 (breaking capacity, limitation class, isolation suitability). It carries tropicalisation per IEC 60068-1. Standard Schneider documentation includes the datasheet, installation instructions, and declaration of conformity covering the applicable EU directives. For specific RoHS/REACH declarations, refer to the manufacturer's product compliance portal using the full order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P10AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P10AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}