{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P10AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P10AC","canonicalUrl":"https://aoctrl.com/schneider/C60H2P10AC","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P10AC","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H2P10AC, Multi9 C60H series, 1P+N miniature circuit breaker, C-curve 10 A, 10 kA breaking capacity at 440 V AC, 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric C60H2P10AC is a 1P+N miniature circuit breaker from the Multi9 C60H range, rated 10 A at 30 °C with a C-curve (magnetic trip 5–10 × In). It occupies 4 modular pitches (36 mm wide) on a 35 mm symmetrical DIN rail, making it a direct drop-in for any Multi9 distribution board — no need to gut the existing layout to swap in a modern unit. Breaking capacity hits 10 kA Icu at 440 V AC (IEC 60947-2), 15 kA at 400–415 V, and 30 kA at 230–240 V — enough headroom for most commercial and light industrial sub-distribution panels. The 1P+N configuration (neutral left, one protected pole) suits single-phase final circuits where you want overcurrent protection on the phase and a switched neutral. Rated operational voltage 440 V AC, insulation voltage 500 V AC — the part is isolation-suitable per IEC 60947-2, so you can use it as a disconnecting means with the contact position indicator showing ON/OFF state through the toggle. Mechanical durability rated at 20,000 cycles — fine for distribution duty where the breaker isn't switched daily. Tunnel-type terminals are straightforward for panel builders. Tropicalisation level 2 per IEC 60068-1 and 95% RH at 55 °C means it handles humid environments without derating — relevant for Southeast Asia or coastal installations.","metaTitle":"Schneider C60H2P10AC MCB, C-Curve 10A 1P+N, 10kA","metaDescription":"Schneider Electric C60H2P10AC miniature circuit breaker, C60H Multi9 range, 10A rated, C-curve, 1P+N, 10kA breaking capacity at 440V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P10AC/miniature-circuit-breaker-c60h-2-poles-10-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P10AC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H2P10AC and how do I get a price?","answer":"The C60H2P10AC is sourced to order against an RFQ through independent distribution. Submit a quote request for current pricing and availability — no stock figures are listed here, but the supply posture is routine for this active Multi9 SKU."},{"question":"What is C60H2P10AC's listed depth (73 mm) on this component line?","answer":"The C60H2P10AC has a depth of 73 mm, width of 36 mm (4 modular pitches), and height of 81 mm. It mounts on a 35 mm symmetrical DIN rail."},{"question":"What compliance documentation does this brand provide for C60H2P10AC?","answer":"The C60H2P10AC is designed to IEC 60947-2, with tropicalisation per IEC 60068-1. It carries suitability for isolation marking and limitation class 3. For specific RoHS, REACH, or UL documentation, request the manufacturer's compliance declaration at quote time — standard for Schneider Multi9 products."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P10AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P10AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-14T23:41:25.508Z","lastPublished":"2026-09-14T23:41:25.508Z","indexable":true}}