{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P16AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P16AB","canonicalUrl":"https://aoctrl.com/schneider/C60H2P16AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P16AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H2P16AB, Multi9 C60 range, miniature circuit breaker, B curve, 16 A, 1P+N, 10-30 kA breaking capacity, 35 mm DIN rail.","salesMarkdown":"The Schneider Electric C60H2P16AB is a C60H-series miniature circuit breaker from the Multi9 range, rated 16 A at 30 °C with a B tripping curve (3–5 × In magnetic trip). It protects a single pole with a switched neutral (1P+N), making it a common choice for single-phase final subcircuits in distribution boards where the neutral is switched alongside the phase. Breaking capacity reaches 30 kA Icu at 230–240 V AC and 10 kA Icu at 440 V AC, both per IEC 60947-2. The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (magnetic solenoid) in one compact package. The 36 mm width (4 modules at 9 mm pitch) fits standard distribution board cutouts. Fixed mounting mode — no plug-in base, so it stays put under vibration or during busbar connection. The neutral position is left, which matches the typical busbar layout in Multi9 boards. Depth of 73 mm and height of 81 mm leave clearance for wiring and enclosure covers. The toggle actuator provides local ON/OFF indication and manual switching. Rated insulation voltage 500 V AC, operational voltage 440 V AC. Mechanical durability rated at 20,000 cycles.","metaTitle":"Schneider Electric C60H2P16AB MCB, C60 Multi9, B Curve 16A 1","metaDescription":"Schneider Electric C60H2P16AB miniature circuit breaker, Multi9 C60 range, B curve, 16 A rated, 1P+N, 10-30 kA breaking capacity, DIN rail mount. Current lifecycle stage. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P16AB/miniature-circuit-breaker-c60h-2-poles-16-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P16AB/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the C60H2P16AB?","answer":"Breaking capacity is 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, and 10 kA at 440 V AC, all per IEC 60947-2. For DC applications, it is rated 25 kA at 125 V DC (2-pole series connection)."},{"question":"What does the B curve mean on this breaker?","answer":"The B curve means the magnetic trip operates at 3 to 5 times the rated current (48–80 A for this 16 A unit). It is typically used for resistive or general-purpose loads where inrush is low — lighting, small transformers, control circuits."},{"question":"Where can I buy the C60H2P16AB?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What compliance documentation is available for the C60H2P16AB?","answer":"The breaker is designed to IEC 60947-2 (breaking capacity, limitation class 3, isolation suitability) and IEC 60068-1 (tropicalisation). Standard Schneider Multi9 documentation includes CE declaration and RoHS/REACH compliance data available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P16AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P16AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}