{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P16AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P16AD","canonicalUrl":"https://aoctrl.com/schneider/C60H2P16AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P16AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, C60H2P16AD, miniature circuit breaker, D curve, 16 A, 1P+N, 10-30 kA breaking capacity.","salesMarkdown":"The Schneider Electric C60H2P16AD is a Multi9 C60H miniature circuit breaker with a D tripping curve, rated 16 A at 40 °C and built for 1P+N (one protected pole plus switched neutral) distribution duty. Breaking capacity runs 30 kA Icu at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC — all per IEC 60947-2. That 10 kA at 440 V is the number to watch if this breaker lands in a 400 V three-phase panel feeding a single-phase subfeed; the 15 kA at 400 V gives a bit more headroom for higher fault-current locations. The 25 kA Icu at 125 V DC (2-pole series connection) means it can also serve DC control circuits or battery-backed buswork, though the 1P+N form factor limits DC use to the 2-pole wiring method. Snaps onto 35 mm symmetrical DIN rail — standard for any European-spec enclosure. At 36 mm wide (4 x 9 mm pitches) and 81 mm tall, it occupies one standard MCB slot plus the neutral pole width; the 73 mm depth leaves clearance behind a 100 mm deep gland plate. The neutral position is left, which matters when ganging multiple breakers on a busbar — verify the busbar lug aligns before torquing down. Rated for operation from -25 °C to 60 °C ambient, storage from -40 °C to 70 °C, and 95 % relative humidity at 55 °C — fine for most indoor panel environments including non-condensing washdown zones. Operating altitude is 2000 m; above that, dielectric withstand and breaking capacity derate per IEC 60947-2.","metaTitle":"Schneider Electric C60H2P16AD Multi9 MCB, D Curve, 16 A, 1P+","metaDescription":"Schneider Electric C60H2P16AD Multi9 C60H miniature circuit breaker, D curve, 16 A rated current, 1P+N, 10-30 kA breaking capacity. Current lifecycle stage. Sourced to order agains","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P16AD/miniature-circuit-breaker-c60h-2-poles-16-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P16AD/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for C60H2P16AD?","answer":"The C60H2P16AD is sourced and quoted to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time."},{"question":"What are the key ratings of C60H2P16AD?","answer":"Rated 16 A at 40 °C with a D curve (magnetic trip 10-14 x In), breaking capacity up to 30 kA at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC per IEC 60947-2."},{"question":"What is the depth of C60H2P16AD?","answer":"The C60H2P16AD has a depth of 73 mm, fitting behind a standard 100 mm deep gland plate."},{"question":"What is the Multi9 range for C60H2P16AD?","answer":"The C60H2P16AD belongs to the Schneider Electric Multi9 range, specifically the C60H series of miniature circuit breakers."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P16AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P16AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}