{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P20AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P20AC","canonicalUrl":"https://aoctrl.com/schneider/C60H2P20AC","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P20AC","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Multi9 series, C60H miniature circuit breaker, C60H2P20AC, 20 A rated, C-curve, 1P+N, 10 kA breaking capacity at 440 V AC, 36 mm width.","salesMarkdown":"The Schneider Electric C60H2P20AC is a 20 A miniature circuit breaker from the Multi9 C60 range, built as a 1P+N unit with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit protection. Rated breaking capacity hits 10 kA Icu at 440 V AC, 15 kA at 400–415 V AC, and 30 kA at 230–240 V AC, all per IEC 60947-2. The limitation class is 3 per IEC 60947-2, meaning it lets through less energy during a fault than a class-2 or class-1 device. That helps with downstream coordination and reduces stress on wiring and connected equipment. Width is 36 mm (4 x 9 mm pitches), which is the standard 2-module width for a 1P+N MCB in most enclosures. Depth is 73 mm, height 81 mm — check your enclosure depth if you are retrofitting into a shallow consumer unit. Wire stripping length is 14 mm.","metaTitle":"Schneider C60H2P20AC MCB, C-Curve 20A 1P+N, 10kA","metaDescription":"Schneider Electric C60H2P20AC miniature circuit breaker, 20A rated, C-curve, 1P+N, 10kA breaking capacity at 440V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"20 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P20AC/miniature-circuit-breaker-c60h-2-poles-20-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P20AC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H2P20AC and what is the lead time?","answer":"The C60H2P20AC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is C60H2P20AC's listed depth?","answer":"The depth is 73 mm."},{"question":"What is the C60H2P20AC's range and series?","answer":"It belongs to the Multi9 range, specifically the C60 product family, with the device short name C60H."},{"question":"What compliance documentation does Schneider provide for C60H2P20AC?","answer":"The MCB carries IEC 60947-2 certification for breaking capacity and isolation suitability. It also conforms to IEC 60068-1 for tropicalisation (2 levels). Standard Schneider documentation includes the datasheet, IEC test certificates, and declaration of performance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P20AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P20AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}