{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P20AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P20AD","canonicalUrl":"https://aoctrl.com/schneider/C60H2P20AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P20AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H series, C60H2P20AD, miniature circuit breaker, 1P+N, 20 A, D curve, 10 kA Icu at 440 V AC.","salesMarkdown":"The C60H2P20AD is a 1P+N miniature circuit breaker from the Schneider Electric Multi9 C60H range, rated 20 A at 40 °C with a D tripping curve (10–14 × In magnetic threshold). It delivers 10 kA Icu at 440 V AC and 30 kA Icu at 230–240 V AC per IEC 60947-2, making it suitable for distribution boards where high inrush loads — motor circuits, transformers, lighting banks — need a delayed magnetic trip to avoid nuisance tripping on startup. The 10 kA Icu at 440 V AC and 30 kA Icu at 230–240 V AC (both per IEC 60947-2) give this breaker solid fault-clearing headroom for most commercial and light industrial panels. The 15 kA rating at 400–415 V AC covers common three-phase distribution voltages. For DC applications, the 25 kA Icu at 125 V DC (2P series connection) handles battery-bank or UPS output protection. The D curve's 10–14 × In magnetic threshold means it tolerates the short-duration current surge of a motor start or a capacitor bank charge without tripping — a common pain point when a C-curve breaker nuisance-trips on the same load. Snaps onto a 35 mm symmetrical DIN rail (per), occupies 4 modular pitches (36 mm width per), and stands 81 mm tall with a 73 mm depth behind the panel. The left-side neutral position and fixed mounting mean it aligns consistently in a multi-row distribution board — no neutral-bar rework when swapping from a different MCB brand. Tropicalisation treatment per IEC 60068-1 (2 levels) and limitation class 3 per IEC 60947-2. The breaker is suitable for isolation (yes, per IEC 60947-2) and includes an ON/OFF indication on the toggle. Earth-leakage protection requires a separate block — not integrated.","metaTitle":"Schneider Electric C60H2P20AD MCB, 20A, D Curve, 10kA","metaDescription":"Schneider Electric C60H2P20AD Multi9 C60H miniature circuit breaker, 20 A rated current, D curve, 10 kA breaking capacity at 440 V AC. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"20 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P20AD/miniature-circuit-breaker-c60h-2-poles-20-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P20AD/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H2P20AD?","answer":"The C60H2P20AD has a breaking capacity of 10 kA Icu at 440 V AC, 15 kA Icu at 400–415 V AC, 30 kA Icu at 230–240 V AC (all per IEC 60947-2), and 25 kA Icu at 125 V DC (2P series)."},{"question":"What does the D curve mean on this breaker?","answer":"The D curve means the magnetic trip threshold is 10–14 × In (200–280 A for the 20 A rating), which delays tripping on high inrush currents typical of motor starts, transformer energization, or capacitor bank charging."},{"question":"Where can I buy C60H2P20AD?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P20AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P20AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}