{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P25AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P25AD","canonicalUrl":"https://aoctrl.com/schneider/C60H2P25AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P25AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H2P25AD, Multi9 C60 series miniature circuit breaker, 25 A rated current, D curve, 1P+N, breaking capacity 10 kA Icu at 440 V AC.","salesMarkdown":"The Schneider Electric C60H2P25AD is a C60H miniature circuit breaker from the Multi9 range, rated 25 A at 40 °C with a D tripping curve (magnetic trip 10–14 x In). It protects a single pole plus neutral (1P+N) and is suited for distribution boards where high inrush loads — motor starting, transformer energisation, discharge lighting — demand a delayed magnetic release to avoid nuisance trips. The 1P+N format means the neutral is switched and protected, not just a solid bar, which is required in some regional wiring rules and for isolation duty (the part carries IEC 60947-2 isolation suitability). Breaking capacity varies with voltage: 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, and 10 kA at 440 V AC (all per IEC 60947-2). At 125 V DC (2-pole series connection) it reaches 25 kA Icu. For a 25 A MCB in a typical 230/400 V panel, the 15 kA at 400 V gives solid headroom above the usual 10 kA prospective short-circuit current in most commercial installations, meaning the breaker can clear a fault without upstream fuse backup in all but the highest-fault locations. The limitation class is 3 per IEC 60947-2, which limits let-through energy enough to protect downstream cables and equipment. Width is 36 mm (4 x 9 mm pitches), depth 73 mm, height 81 mm — fits standard distribution board cutouts. The toggle handle gives clear ON/OFF indication and a contact position indicator confirms isolation status. Ambient operating range is –25 to 60 °C, storage –40 to 70 °C, with tropicalisation per IEC 60068-1 (2-class humidity resistance).","metaTitle":"Schneider Electric C60H2P25AD C60 MCB, 25 A, D Curve, 1P+N,","metaDescription":"Schneider Electric C60H2P25AD miniature circuit breaker, 25 A rated current, D curve, 1P+N, breaking capacity 10 kA at 440 V AC. Multi9 range, DIN rail mount. Current lifecycle sta","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"25 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P25AD/miniature-circuit-breaker-c60h-2-poles-25-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P25AD/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H2P25AD?","answer":"The breaking capacity is 30 kA Icu at 230–240 V AC, 15 kA at 400–415 V AC, 10 kA at 440 V AC, and 25 kA at 125 V DC (2-pole), all per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P25AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P25AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}