{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P32AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P32AC","canonicalUrl":"https://aoctrl.com/schneider/C60H2P32AC","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P32AC","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Multi9 range, C60H miniature circuit breaker, C60H2P32AC, 1P+N, 32 A, C curve, 10 kA at 440 V AC.","salesMarkdown":"The C60H2P32AC is a 1P+N miniature circuit breaker from the Schneider Multi9 range, rated 32 A at 30 °C with a C curve (magnetic trip at 5–10× In). Breaking capacity hits 10 kA Icu at 440 V AC (IEC 60947-2), 15 kA at 400–415 V, and 30 kA at 230–240 V — enough for most commercial and light industrial distribution panels. The 1P+N configuration switches the phase and provides a switched neutral, which is common in single-phase final subcircuits where isolating both conductors is required. The thermal-magnetic trip unit gives overload protection via a bimetal strip and short-circuit protection via a solenoid. Earth-leakage protection requires a separate block — not integrated.","metaTitle":"Schneider C60H2P32AC MCB, C Curve 32 A 1P+N, 10 kA","metaDescription":"Schneider Electric C60H2P32AC miniature circuit breaker, 32 A rated current, C curve, 1P+N, 10 kA breaking capacity at 440 V AC. Multi9 range, DIN rail mount. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P32AC/miniature-circuit-breaker-c60h-2-poles-32-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P32AC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H2P32AC and get a price?","answer":"The C60H2P32AC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of C60H2P32AC?","answer":"The C60H2P32AC has a breaking capacity of 10 kA Icu at 440 V AC, 15 kA at 400–415 V AC, 25 kA at 125 V DC (2P), and 30 kA at 230–240 V AC, all conforming to IEC 60947-2."},{"question":"What is the closest alternative to C60H2P32AC in the same family?","answer":"Within the Multi9 C60 range, the closest peer is the C60H-DC variant for DC circuits, or the C60N/C60L versions which differ in breaking capacity (lower for C60N, higher for C60L). The C60H2P32AC is the 32 A, C-curve, 1P+N, 10 kA variant — the main deciding factor is the required SCCR at your system voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P32AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P32AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}