{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P4AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P4AD","canonicalUrl":"https://aoctrl.com/schneider/C60H2P4AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P4AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60 series, C60H2P4AD miniature circuit breaker, 1P+N, D curve, 4 A rated, 30 kA breaking capacity at 230-240 V AC.","salesMarkdown":"The Schneider Electric C60H2P4AD is a Multi9 C60 series miniature circuit breaker (MCB) with a D tripping curve, rated 4 A at 40 °C. It protects a single pole plus neutral (1P+N) in AC distribution circuits. Breaking capacity reaches 30 kA Icu at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC, all conforming to IEC 60947-2. Mounts on a 35 mm symmetrical DIN rail (EN 60715), occupying 4 modular pitches of 9 mm each — 36 mm total width. Dimensions: 81 mm height, 36 mm width, 73 mm depth. Tropicalisation level 2 per IEC 60068-1 means the breaker is treated against humidity and fungal growth — relevant for installations in warm, damp environments. Limitation class 3 per IEC 60947-2 indicates the let-through energy (I²t) is limited, reducing stress on downstream components during a fault.","metaTitle":"Schneider Electric C60H2P4AD Multi9 C60 MCB, D Curve, 4 A, 1","metaDescription":"C60H2P4AD miniature circuit breaker, 4 A rated, D curve, 10-14 x In magnetic trip, 30 kA breaking capacity at 230-240 V AC. Current lifecycle stage, available to order. DIN rail mo","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"4 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P4AD/miniature-circuit-breaker-c60h-2-poles-4-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P4AD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the C60H2P4AD and get a price?","answer":"The C60H2P4AD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of the C60H2P4AD?","answer":"Breaking capacity is 30 kA Icu at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC, all per IEC 60947-2. At 125 V DC (2 poles in series) it is rated 25 kA Icu."},{"question":"What compliance documentation is available for the C60H2P4AD?","answer":"The breaker carries IEC 60947-2 certification for breaking capacity and isolation suitability. Tropicalisation per IEC 60068-1 level 2 is confirmed. RoHS, REACH, and UL documentation should be verified against the specific manufacturing date code — contact your sourcing desk for the compliance pack matching your lot."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P4AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P4AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}