{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P50AB","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P50AB","canonicalUrl":"https://aoctrl.com/schneider/C60H2P50AB","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P50AB","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, C60H2P50AB, miniature circuit breaker, 50 A, B-curve, 2-pole, 10 kA Icn per EN 60898, 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric C60H2P50AB is a 2-pole miniature circuit breaker from the Multi9 C60H range, rated 50 A with a B-curve trip characteristic. The C60H2P50AB carries a 10 kA Icn rating at 230/400 V AC per EN 60898 — that's the standard for domestic and commercial final circuits. Under IEC 60947-2, the Icu (ultimate breaking capacity) goes higher: 15 kA at 400–415 V AC, 25 kA at 125 V DC (2-pole series trip), and 30 kA at 230–240 V AC. The Ics (service breaking capacity) is 7.5 kA at 230/400 V AC per EN 60898, meaning it can clear a fault at that level and still be used again afterward. For a 50 A feeder, that gives decent selectivity with upstream devices rated 25 kA or higher — common in a sub-distribution board fed from a 100 A or 160 A MCCB. The 2-pole body takes 4 modules of 9 mm pitch — 36 mm wide total, 81 mm tall, 73 mm deep. That's a standard footprint for a 2-pole MCB; it fits any DIN-rail enclosure or distribution board without surprises.","metaTitle":"Schneider C60H2P50AB MCB, 50A, Curve B, 2P, 10kA","metaDescription":"Schneider Electric C60H2P50AB miniature circuit breaker, 50A rated, B-curve, 2-pole, 10kA breaking capacity per EN 60898. Multi9 range, DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"50 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P50AB/miniature-circuit-breaker-c60h-2-poles-50-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P50AB/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for C60H2P50AB?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time."},{"question":"What is C60H2P50AB's breaking capacity?","answer":"The Icn is 10 kA at 230/400 V AC per EN 60898. Under IEC 60947-2, the Icu reaches 15 kA at 400–415 V AC, 25 kA at 125 V DC (2-pole), and 30 kA at 230–240 V AC."},{"question":"What does the B-curve mean on this breaker?","answer":"The magnetic trip threshold is 3 to 5 times the rated current (150–250 A for the 50 A version). That's suited for resistive or low-inrush loads — lighting, heating, control transformers — where a C-curve (5–10x) would be too slow to trip on a hard short."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P50AB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P50AB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}