{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P50AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P50AD","canonicalUrl":"https://aoctrl.com/schneider/C60H2P50AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P50AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, miniature circuit breaker, C60H2P50AD, 2P, 50 A, D curve, 10 kA Icn at 230/400 V AC.","salesMarkdown":"The C60H2P50AD is a 2-pole miniature circuit breaker from the Schneider Electric Multi9 C60H range, rated 50 A at 40 °C with a D tripping curve (magnetic trip 10–14 × In). Breaking capacity is 10 kA Icn per EN 60898 at 230/400 V AC, and under IEC 60947-2 the ultimate breaking capacity (Icu) reaches 15 kA at 400–415 V AC and 30 kA at 230–240 V AC. For a 50 A feeder in a typical commercial or light-industrial panel, 10 kA at the service entrance is adequate for most installations; the higher Icu figures confirm the breaker can clear a fault at the bus without welding contacts, even when the available fault current is higher than the Icn rating. The service breaking capacity (Ics) is 7.5 kA per EN 60898 at 230/400 V AC, meaning after clearing a fault at that level the breaker remains functional and can be reclosed — not just a one-shot device. This matters for selectivity studies: if the upstream device is a 63 A moulded-case breaker with a higher Icu, the C60H2P50AD can be coordinated to let the downstream MCB clear first. Mounts on a 35 mm symmetrical DIN rail (EN 60715) and occupies 4 modules of 9 mm pitch — 36 mm total width. For panel builders, the 73 mm depth leaves clearance for standard 80 mm deep enclosures. The toggle handle provides local ON/OFF indication and a contact position indicator confirms the state of the moving contacts — useful for lockout/tagout verification during maintenance.","metaTitle":"Schneider Electric C60H2P50AD MCB, 50 A, 2P, D Curve, 10 kA","metaDescription":"Schneider Electric C60H2P50AD miniature circuit breaker, 50 A rated current, 2 poles, D curve, 10 kA breaking capacity per EN 60898. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Standards":"EN 60898 IEC 60947-2","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 3.5 N.m upside 3.5 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"50 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P50AD/miniature-circuit-breaker-c60h-2-poles-50-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P50AD/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C60H2P50AD?","answer":"The C60H2P50AD has a rated breaking capacity of 10 kA Icn at 230/400 V AC per EN 60898, and an ultimate breaking capacity (Icu) of 15 kA at 400–415 V AC and 30 kA at 230–240 V AC per IEC 60947-2."},{"question":"What is C60H2P50AD's listed depth (73 mm) on this component line?","answer":"The C60H2P50AD has a depth of 73 mm, a width of 36 mm (4 x 9 mm pitches), and a height of 81 mm."},{"question":"What compliance documentation does this brand provide for C60H2P50AD (RoHS, REACH, UL, IEC)?","answer":"The C60H2P50AD is certified to EN 60898 and IEC 60947-2. It carries tropicalisation class 2 per IEC 60068-1 and limitation class 3 per IEC 60947-2. RoHS and REACH compliance documentation is available from the manufacturer upon request."},{"question":"Where can I buy C60H2P50AD?","answer":"The C60H2P50AD is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P50AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P50AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}