{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H2P6AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H2P6AC","canonicalUrl":"https://aoctrl.com/schneider/C60H2P6AC","factsUrl":"https://aoctrl.com/api/mcp/products/C60H2P6AC","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Multi9 C60H, miniature circuit breaker, C60H2P6AC, 1P+N, 6 A, C-curve, 10 kA breaking capacity at 440 V AC, DIN rail mount.","salesMarkdown":"## What this MCB does on the panel The Schneider Electric C60H2P6AC is a 1P+N miniature circuit breaker from the Multi9 C60H series, rated 6 A with a C-curve trip characteristic. It protects a single phase and its neutral on a 230/400 V AC distribution board, with a 10 kA interrupting capacity at 440 V AC per IEC 60947-2 — enough for most commercial and light industrial sub-distribution panels where the fault current stays under that ceiling. Neutral is on the left, which matters when you're laying out busbars or pre-wired assemblies. The toggle gives positive ON/OFF indication and a contact position indicator confirms the state even if the handle is forced. The C60H2P6AC carries a 30 kA Icu at 230...240 V AC and 15 kA at 400...415 V AC, so it coordinates well with an upstream 63 A or 100 A molded-case breaker in a typical 2-level distribution scheme. The 10 kA at 440 V AC is the worst-case rating for a 3-phase line-to-line fault on a 400 V system. Limitation class 3 per IEC 60947-2 means it lets through less energy than a class-2 breaker — useful for protecting downstream equipment and reducing arc-flash energy at the panel.","metaTitle":"Schneider Electric C60H2P6AC MCB, C-Curve, 6 A, 1P+N, 10 kA","metaDescription":"Schneider Electric C60H2P6AC miniature circuit breaker, 6 A, C-curve, 1P+N, 10 kA breaking capacity at 440 V AC. Multi9 range, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"36 mm","Height":"81 mm","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of product":"C60","Breaking capacity":"10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A at 30 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"15 kA conforming to IEC 60947-2 - 12...440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 60 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H2P6AC/miniature-circuit-breaker-c60h-2-poles-6-a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H2P6AC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H2P6AC?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of C60H2P6AC at 440 V?","answer":"The breaking capacity is 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2. At 230...240 V AC it rises to 30 kA Icu."},{"question":"What is the closest pin-compatible alternative to C60H2P6AC in this component family?","answer":"Within the Multi9 C60H range, the C60H2P6AC is a 1P+N 6 A C-curve unit. A direct pin-compatible sibling would be a different current rating (e.g., 10 A or 16 A) or curve (B or D) in the same C60H 1P+N form factor — same footprint, same DIN-rail mount, same terminal layout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H2P6AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H2P6AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}