{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C60H4P16AD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C60H4P16AD","canonicalUrl":"https://aoctrl.com/schneider/C60H4P16AD","factsUrl":"https://aoctrl.com/api/mcp/products/C60H4P16AD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric C60H4P16AD, Multi9 C60H series, 4-pole miniature circuit breaker, D-curve, 16 A rated current at 40 °C, thermal-magnetic trip, 35 mm DIN rail mount.","salesMarkdown":"The C60H4P16AD is a 4-pole D-curve miniature circuit breaker from Schneider Electric's Multi9 C60H range, rated 16 A at 40 °C. Breaking capacity is multi-tiered: 10 kA Icn per EN 60898 at 230/400 V AC covers standard distribution panels, while the IEC 60947-2 ratings go higher — 30 kA Icu at 230...240 V AC and up to 50 kA Icu at 250 V DC 4P — giving headroom for high-fault industrial switchboards where SCCR coordination matters. The 4-pole form (4 protected poles) suits three-phase plus neutral applications where all conductors need overcurrent protection. The toggle provides local ON/OFF indication. Ambient operation range is -25 to 60 °C, storage -40 to 70 °C, with tropicalisation class 2 per IEC 60068-1 for humid environments up to 95% RH at 55 °C. Dual-rated to IEC 60947-2 (industrial) and EN 60898 (household/residential) standards. Suitability for isolation confirmed per IEC 60947-2. Earth-leakage protection requires a separate Vigi block — not integrated.","metaTitle":"Schneider Electric C60H4P16AD C60H MCB, 4P D-Curve 16 A","metaDescription":"Schneider Electric C60H4P16AD miniature circuit breaker, 4-pole D-curve, 16 A rated current at 40 °C. Breaking capacity 10 kA (EN 60898) to 50 kA (IEC 60947-2). Active lifecycle, s","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Multi9","Width":"72 mm","Height":"81 mm","Standards":"IEC 60947-2 EN 60898","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"C60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"C60","Breaking capacity":"10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2","Device short name":"C60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m upside 2 N.m downside","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A at 40 °C","Trip unit technology":"Thermal-magnetic","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals16 mm² flexible Tunnel type terminals25 mm² rigid","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"12...440 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to EN 60898 - 230/400 V AC 50/60 Hz 15 kA conforming to IEC 60947-2 - 230...240 V AC 50/60 Hz 5 kA conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA conforming to IEC 60947-2 - 400...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/C60H4P16AD/miniature-circuit-breaker-c60h-4-poles-16-a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C60H4P16AD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C60H4P16AD?","answer":"The C60H4P16AD is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of C60H4P16AD?","answer":"Rated 16 A at 40 °C, 4-pole D-curve with magnetic trip at 10-14 x In, breaking capacity up to 50 kA Icu at 250 V DC 4P per IEC 60947-2, and 10 kA Icn at 230/400 V AC per EN 60898."},{"question":"What standards does the C60H4P16AD comply with?","answer":"Compliant with IEC 60947-2 and EN 60898, with suitability for isolation per IEC 60947-2 and limitation class 3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C60H4P16AD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C60H4P16AD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}